© 2021 Hoymiles Power Electronics Inc. All rights reserved.
12
Single-phase Microinverter User Manual
*Note: Under circumstances that require
removing the inverter AC cable from bus
port, please use the AC connector unlocking
tool and insert the tool into the side of the
AC port.
Step 3. Install AC End Cable
A) Prepare an AC end cable with proper
length and insert one side of the cable
into the cap. Match the L, N and Ground
lines into the appropriate slots. Tighten
the screws, and then reinsert the cap
tightly in the port. Plug the upper cover
back to the bus connector.
Coated with solder
B) Connect the other side of the AC end cable to the distribution box, and wire it to the local grid network.
Step 4. Create an Installation Map
A) Peel the removable serial number label
from each microinverter (the position of
the label is shown below).
B) Affix the serial number label to the
respective location on the installation
map.
N S E W
(circle one)
Panel Group:
Azimuth:
Tilt:
Sheet _ of _
Customer Information:
DTU Serial Number:
Step 5. Connect PV Modules
A) Mount the PV modules above the
microinverter.
B) Connect the PV modules’ DC cables to
the DC input side of the microinverter.
Step 6. Energize the System
A) Turn on the AC breaker of the branch circuit.
B) Turn on the main AC breaker of the house. Your system will start to generate power after about two
minutes of waiting time.