Hoymiles DTU-Pro User Manual Download Page 13

© 2021 Hoymiles Power Electronics Inc. All rights reserved.

12

Single-phase Microinverter User Manual

6.  Site Creation on S-Miles Cloud (Hoymiles Monitoring Platform)

A.  Install the Hoymiles Installer App by searching “Hoymiles” at App Store (iOS) or Google Play (Android).

B.  Open the app and log in with your installer account name and password. If you are a new installer with 

Hoymiles, apply for an installer account from your distributor in advance.

C.  Add Plant, select the “Plant” tab on the bottom, then select “

” on the top right side of the page.

D.  Select “Quick” for a single DTU and “Professional” for multiple DTUs.

E.  Fill in the plant details accordingly, and press “Next” after this is complete.

F.  Press “Add DTU SN”, scan the DTU SN (or you can manually input the SN) and press “Next” after this is 

complete. 

G.  Press “Start pairing” and choose the angle and tilt based on the installation site.

H.  Scan the Microinverter SN (or you can manually input the SN) and check the box after completing each 

SN input. Press “Finish” once all Microinverter SNs have been added.

I. 

Disable the Scan function on the top right side and design the layout based on the installation site. 
Check the box on the top right side, and then select “Next” after completing the design.

J. 

Upload a picture of the site and select “Finish” to complete the site creation.

K.  The new site will appear on the plant list in the installer account.

L.  Press the “Networking” button after the plant is created.

M.  Wait about 30 minutes, after which the plant will be displayed as online, and all the Microinverter SNs 

will be found.

Summary of Contents for DTU-Pro

Page 1: ...Open Energy for All Single phase Microinverter USER MANUAL DTU Pro Region Global V202105 hoymiles com...

Page 2: ...rm 03 3 Interface Layout 03 3 1 Interface Layout 03 3 2 Export Management Function RS485 port 04 3 3 Remote Active Power Control RS485 port 04 3 4 DRM Port 05 3 5 Local Installation Assistant 05 4 DTU...

Page 3: ...the DTU without approval from Hoymiles If the DTU is damaged send the DTU back to your installer for repairing replacement Disassembling the DTU without approval from Hoymiles will invalidate the rema...

Page 4: ...onitoring Platform The DTU communicates wirelessly with the microinverters via 2 4 GHz Proprietary RF Nordic and collects the operation data of the system Meanwhile the DTU connects to the Internet vi...

Page 5: ...tain value Type 3 Production and Consumption Monitoring enable to measure the PV generation with high accuracy c Installation Diagram PV Module PV Module Hoymiles MI 600 Hoymiles MI 600 Solar Local Lo...

Page 6: ...traints from other active DRMs 3 5 Local Installation Assistant Local Installation Assistant is a new function integrated with DTU Pro Download the Installer App for installer distributor use only bef...

Page 7: ...ation conditions described in both the DTU and microinverter manuals The distance between the microinverter and the DTU needs to be within the required range 4 2 Basic Conditions Required Before insta...

Page 8: ...ll optional 7 Connect to the Internet 8 Start procedure 9 Normal operation 4 5 Preparation A Download the Hoymiles Installer App B Check the box for following items Hoymiles DTU Pro Two Antennas Adapt...

Page 9: ...tenna at support hoymiles com Step 2 Choose an installation location Install on the top floor to increase signal strength Install near the center of the PV array Install at least 0 5 m above the groun...

Page 10: ...nnas are perpendicular to the table a Plug in the power adapter to power the DTU b Set up with Internet c Use the smartphone tablet to open the Installer App and login Locate Me on the bottom of the p...

Page 11: ...2021 Hoymiles Power Electronics Inc All rights reserved 10 Single phase Microinverter User Manual...

Page 12: ...allation map A Peel the serial number label as circled below from the DTU and place it on the installation map B Complete the system information of the installation map as shown below NSEW circle one...

Page 13: ...ete F Press Add DTU SN scan the DTU SN or you can manually input the SN and press Next after this is complete G Press Start pairing and choose the angle and tilt based on the installation site H Scan...

Page 14: ...by installer in the previous step Section 6 Step B and press Login c Customers will be able to view all details once the data starts to upload Normally it will take around 30 minutes for the first da...

Page 15: ...2021 Hoymiles Power Electronics Inc All rights reserved 14 Single phase Microinverter User Manual 9 View Phone App Download mobile phone app and view plant information...

Page 16: ...n Microinverter communication Fault state LED States LED Indicator Status Description All Firmware upgrading Starting up DTU power on DTU power off DTU is communicating with the S Miles Cloud Hoymiles...

Page 17: ...pp Local app Power Supply Type External plug in adapter Adapter input voltage frequency AC 100 to 240 V 50 or 60 Hz Adapter output voltage current 5 V 2 A Power consumption 2 5 W typical 5 W maximum M...

Reviews: