INSTALLATION INSTRUCTIONS
XFLE-TR Series
04/12/2018
Doc#1025-000244-001 RV0
Installation Steps
1.
Secure trunnion on mounting surface using expansion bolts
(sold by others). Mount hole details are provided on previous
page.
2.
Attach luminaire to the trunnion using trunnion bolt and nuts.
Hand tighten trunnion bolt.
3.
Ensure power is off, and then make electrical connections.
Connect wires; white wire to “Neutral”, black wire to “Line”,
green wire to “Ground”.
4.
Aim fixture –
a.
Aim to desired point,
b.
Use set screws, both sides, to hold orientation.
(philips-head screwdriver)
5.
Tighten trunnion bolts. (requires Metric #14 wrench)
After installation, please
Check that the lighting fixture is firmly fixed.
Check that wires are connected correctly.
At last, turn on the power, and check function.
Mounting on round poles:
Use XLE-TR-RPM (sold separately) For 100W, 150W,
&230W luminaires. (φ2.0” – φ4.3”)
Use XLE-TR-RPML (sold separately) For 300W luminaires.
(φ2.0” – φ4.7”)
Mounting on square poles:
Use XLE-TR-SPM (sold separately) For 100W, 150W,
&230W luminaires. (2.0” – 3.5”)
Use XLE-TR-SPML (sold separately) For 300W luminaires.
(2.0” – 3.9”)
Additional Product Images
# 1025-000230-050 RV00
100W, 150W Luminaire
230W Luminaire
300W Luminaire
Set screw
Trunnion bolt
Lock nut
Lock washer