Houghton BELAIRE A3400 Owner'S Manual Download Page 10

7

Note

The outdoor unit weighs about 45kg

/

99 lbs

use appropriate manual handling precautions

.

Use the M8 bolts and check if the holes are

aligned with the holes of the plenum mounting

bracket

.

If not then use a long screw driver

inserted up through the two holes to assist with

alignment

.

It is the installers responsibility to ensure that

local

wiring

regulations

are

followed

when

connecting to mains supply

.

Look upward from inside the caravan

,

and locate the

terminal block as shown in the figure below

.

Connect the external power lines to the 3

-

pole

terminal block and note the positions of the active

,

neutral and ground

.

3 Pole terminal block

Connect the power supply

Connect the storage battery power supply

Note

Match the corresponding active

,

neutral and

the ground wire and firmly tighten up the screws

to make sure the power line is not loose or

improperly connected

,

otherwise a short circuit

or fire could be caused

.

Connect the wall-mounted switch

Connect M8 bolts

,

washers and fixing metal plates in

order shown

.

Lift the plenum mounting bracket toward the air-

conditioner

.

Insert M8 bolts

,

washers and metal clamping bars

into the 4 corner holes of the plenum mounting

bracket

.

Start the bolts into their receiving threads by

hand to ensure engagement

.

Ensure all bolts have started correctly for at least 2 or

3 rotations to avoid cross threading

.

Installation of M8 bolts

(Applies

 

to

 

Units

 

with

 

LED

 

lighting)

Locate

 

the

 

pair

 

of

 

12V

 

DC

 

supply

 

cables

 (

Red

 & 

Black

 

pair 

).

Connect

 

these

 

cables

 

to

 

the

 

12V

 

DC

 

supply from your vehicle

.

Connect red cable to  +12V

 

and

 

black

 

cable

 

to

 

0V

.

DC

 

supply

 

shall

 

be

 

fused

 

and

 

regulated

 

to

 

not

 

exceed 15V.

Locate

 

the

 

pair

 

of

 

blue

 

wires

 

labelled " Wall Switch "

  

These  wires  can 

 

be 

 

connected

  

to

  

a

  

NC

  

or

  

NO switch

 

to

 

allow

 

for

 

control

 

of

 

LED

 

lighting

 

via

 

a familiar

 

 

wall

 

switch

DO NOT APPLY VOLTAGE TO THESE LINES.

 

Red

 

Black  Bule  Bule

Ensure the metal clamping bars align with the

corresponding

recess

in

the plenum

mounting

bracket as the bolts are tightened

.

Evenly tighten up all four bolts

.

Note

Tighten the bolts to 10

-

12 Nm

(

8

-

9 lbf ft

)

torque

.

Do not exceed 12Nm

(

9 lbf ft

).

Do

 

not

 

use

  

Impact 

 

drivers 

 

to

 

tighten 

 

the

 

hold

 

down

 

bolts

Impact

 

drivers

 

will

 

apply

 

very 

 

high 

 

torques 

 

and

  

damage 

 

the 

 

air

-

conditioner

.  

Use

 

only

 

torque

 

limited

 

tools

 

to

 

tighten

 

these

 

bolts

(Applies

 

to

 

Units

 

with

 

LED

 

lighting)

Summary of Contents for BELAIRE A3400

Page 1: ...H3400 A3400 A3401 OWNERS MANUAL CARAVAN AIR CONDITIONER MODEL MODEL NUMBER SERIAL NUMBER DATE PURCHASED For your safety please read this manual carefully before using the product...

Page 2: ...s in this manual All the contents with this Prohibition logo are about the actions that shall be prohibited or else the air conditioner may be damaged or the user s personal safety may be endangered A...

Page 3: ...Product Introduction 2 Packing List 3 Installation Guidance 4 Quick Start Guide 10 Remote control operation 11 Product Maintenance 18 Specifications 19 Exploded Diagram and Parts List 20 Trouble Shoo...

Page 4: ...ce with the instructions of this manual Incorrect installation methods or alteration of the product may cause damage to the product or personal injuries to the user Be careful when installing the unit...

Page 5: ...temperatures turn on the air conditioner in advance during the morning Adjust the set temperature of the remote control to prevent frequent starting or stopping of the unit C Condensation When warm m...

Page 6: ...Plenum assembly 1 Accessories fixing devices 7 M8 120mm hex head bolts 4 8 Metal clamping bars 4 9 Large M8 washers 4 10 Plenum screw ST4 2 19 pan head screws 4 11 Countersunk head self tapping screws...

Page 7: ...ll be able to support the air conditioner s weight 45kg 99 lbs Minimum thickness of roof is 25mm 1 maximum thickness of roof is 70mm 2 3 4 If the roof s thickness is greater than 70mm 2 3 4 you can pu...

Page 8: ...ioned air back to the return air intake If an outlet is closer than 400mm from an obstruction then it should be sealed closed Failure to do this will result in a unit that frequently cycles on and off...

Page 9: ...f mount Installation of outdoor unit Direction of travel Plenum position Position of rooftop unit Square hole 14 3 16 14 3 16 This side up This side up sealant path 14 3 16 13 15 16 6 7 8 22 5 8 44 3...

Page 10: ...rd the air conditioner Insert M8 bolts washers and metal clamping bars into the 4 corner holes of the plenum mounting bracket Start the bolts into their receiving threads by hand to ensure engagement...

Page 11: ...nel Please note that colors of the wires should be match yellow to yellow red to red etc Connect LED light power cable Attach the plenum assembly to the plenum mounting bracket by engaging the two par...

Page 12: ...n is completed Installation of the air filter Adjust direction and angle of louver by moving blade around its axis The 2 blades move together Louvers on opposite sides are symmetrical Adjust direction...

Page 13: ...or starts Select HEAT mode adjust the setting temperature to three degrees higher than the room temperature the unit will start to blow warm air after the compressor starts Press the LIGHT key turn on...

Page 14: ...11 Remote control operation Standard remote control...

Page 15: ...C 12 Plenum display Touch screen key Temperature display Mode display Remote control for units with LED lighting...

Page 16: ...ess the key select the mode Press the key to select Low Medium High fan speeds The plenum will display and the indoor environment temperature Low Medium High COOL mode Press the key select the mode Pr...

Page 17: ...e mode Press the up key to increase the room temperature Press the FAN key to select different speed and the plenum will display and the setting temperature AUTO mode Press the key select the mode Pre...

Page 18: ...eit Turn off Press the on off key again unit turns off and the plenum and remote control will be blank C F Note When in the AUTO mode according to the difference between the setting temperature and th...

Page 19: ...gain clock and programmed time to turn unit on and off When all setup is done after 10 flashes it will return to clock display Timing to turn on Press the TIMER key until ON flashes and shows the time...

Page 20: ...by directing it towards the plenum which will beep once when a signal is received When the unit is on press the DISPLAY key on the remote control the plenum control LED display can be turned on and o...

Page 21: ...cked for tightness 3 months after the first installation of the product These bolts should be regularly inspected every 12 months through out the air conditioner s life Product Maintenance Filter The...

Page 22: ...5 15 5 Maximum design pressure 2900kPa 550PSIG 550PSIG Minimum design pressure 1840kPa 236PSIG 236PSIG Maximum air flow 150l s 318 CFM 318 CFM Installed weight 45 3 kg 99 7 lbs 99 7 lbs Outdoor unit d...

Page 23: ...20 Exploded Diagram and Parts List...

Page 24: ...8 1220 00 ZL Evaporator components 1 17 4708 1000 15 Pipe clamp 1 18 4708 1230 06 Pipe bracket 2 19 4708 1000 14 Accumulator holder 1 20 4708 1000 06a Compressor 1 H3400 7398 1000 06 Compressor 1 A340...

Page 25: ...0 01 ZH2 Plenum assembly 1 H3400 with LED lighting 4709 1000 01 DM Plenum assembly 1 H3400 without LED lighting 4709 1000 01 Plenum assembly 1 A3400 A3401 35 4708 1241 01 d Display board 1 36 4709 100...

Page 26: ...te control to set required temperature below the current room temperature The compressor will delay a re start for three minutes Check that the heating mode is selected and the plenum display shows Us...

Page 27: ...24 Circuit Diagram H3400 WIRING DIAGRAM with LED lighting H3400 WIRING DIAGRAM without LED lighting 220 240VAC 50Hz...

Page 28: ...25 A3400 A3401 WIRING DIAGRAM 115VAC 60Hz...