![HotWire TR8100 DUAL Control Instructions Download Page 3](http://html1.mh-extra.com/html/hotwire/tr8100-dual-control/tr8100-dual-control_instructions_2170512003.webp)
Installation and Wiring
Carefully separate the front half of the thermostat from the back plate by placing a
small flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged into the front half of
the thermostat. Place the thermostat front half somewhere safe. Terminate the
thermostat as shown in the diagrams below.
Screw the thermostat back plate onto the flush box
Re-connect the thermostat ribbon cable and clip the two halves together.
Holiday Function
Temporary Temperature Override
With thermostat turned off, press and hold OFF for 5 seconds until you can
see -- : -- on LCD.
Manual Mode
Press
MODE
to select Auto/Manual mode. In Manual mode(
), the
thermostat maintains a constant set temperature manually set by the user.
Simply press the temperature and increase it to the required level.
In Auto mode, the thermostat executes the preprogrammed schedules.
The Holiday function reduces the temperature in your room to the frost
protection temperature. The thermostat will maintain this temperature for the
duration of the holiday and will then automatically return to the programme
mode on your return.
Touch the temperature display, and it will start to flash. Use up or down buttons
to adjust. Press
DONE
to accept, and you will see “Override” above the
temperature display. Thermostat will maintain the new set temperature until the
next programmed event (comfort level). To cancel the override setting, press
Run Schedule
Press
HOLIDAY
enter the duration of your holiday by or
or
Press
DONE
To cancel a Holiday, reduce the holiday period to 00 days.
Lock the Keypad
To lock the keypad, press and hold the top left corner of display for 5 seconds,
you will see a lock symbol . To unlock, repeat the steps above and the lock
symbol will disappear.
Reset to Factory Setting
This product should be installed by
a qualified electrician.
Connect green wires to house earth.
Hotwire
Thermostat
Instructions
The following diagram shows how to connect your Hotwire Under Tile Heating
to your thermostat. Simply replicate the following for a second zone or refer to
the manufacturers instructions for subsequent devices.
LOAD (16A)
FEED
(230 VAC)
Floor Sensor
L
N
Brown wire from Heated T
owel Rail
Brown wire from floor heating element
Blue wire from both floor heating and towel rail.
Power
L 2
L 1