9
Maintenance
Optional — Water Inlet Solenoid
A water inlet solenoid can be added to the machine that
will open only when the machine is running or in
standby. The solenoid closes when the machine is off to
prevent possible water overflow when unattended.
Installation
•
Connect a 24V/AC normally closed solenoid on
the water inlet, contact local Hotsy dealer for
solenoid options.
•
Connect solenoid to the remote terminal using
16 ga minimum wire
•
Wire solenoid to remote terminal according to
figure below
Before powering up machine, fill float tank to prime the
system.