![Hotstart OGM Installation & Operation Manual Download Page 21](http://html.mh-extra.com/html/hotstart/ogm/ogm_installation-and-operation-manual_2170305021.webp)
15
installation
&
operation
manual
|
oxm
/
ogm
heating
system
A
B
C
D
E
F
DELTA
WYE
G
A.
Element
assembly bolts
B.
Element
assembly
C.
Element gasket
D.
Heating tank
flange
E.
Heating tank
elements
F.
Heating tank
G.
Cable gland
Figure 15. Removing and replacing the heating tank
element. The heating system should be drained,
cleaned and flushed annually. See
SECOIO 5.3
.
Figure 16. The cable
gland as shown
connected to the
element assembly.
Unscrew to remove
element wiring.
Figure 17. Heating
tank element phase
configurations. Replacement
elements may be a different
phase configuration.