System Maintenance & Troubleshooting
This section describes maintenance and troubleshooting procedures for the Hotstart
Battery Charger System.
System Maintenance
Disconnect all power prior to performing any system maintenance.
WARNING
Electrical Connections
Excessive vibration will eventually cause terminals to loosen. Periodically check
and tighten all electrical connections.
System Mounting
Excessive vibration may cause mounting bolts to loosen. Periodically check and
tighten all mounting bolts.
Cleaning Cooling Passages
In the event the forced air cooling passages get a dust or lint buildup, wipe the
exterior surfaces with a clean dry cloth. The interior cooling passages can be
blown clean with dry air. Never attempt to use liquid cleaners inside the unit.
Troubleshooting
Symptom Possible
Causes Solutions
Charger is not
charging
Main breaker tripped
Secondary breaker tripped
No power
Reset or test circuit breaker
Reset or test circuit breaker
Test the line power source