Hotron 3H-IR14 User Manual Download Page 2

CAUTION

MP-10137

'13 05

Adjust the detection pattern either 0

or +5

by

moving the angle of Body.

7. ADJUSTING SENSITIVITY

2. If the sensor does not detect
even if a person enters the
detection area, please increase
the sensitivity.

After rechecking, if there is still a problem, please contact us or your dealer.

Adjust the detection pattern. Remove moving object.

Problem

Possible Cause

Solution

Door opens and closes
for no apparent reason
(Ghosting)

The sensor detects door movement

Adjust detection depth away from the door.

Door does not
operate

Door operates
intermittently

Door operate by itself

Tighten or reconnect the connector.

Apply proper voltage to the sensor. (AC/DC 12-24V)

Dust, frost or water droplet on the sensor lens

Wipe Detection Window clean and install a weather cover if necessary

Chemicals such as thinner, alcohol use is prohibited to use.

Sensitivity too low

Inappropriate detection area

Turn up sensitivity

Adjust the detection pattern.

There is a moving object in the detection range.
Detection pattern too far from the door,
detecting people passing by.
Sensitivity too high

Turn down the sensitivity.

Another sensor is too close by.

Change the frequency to each sensor.

The condition of detection area is varing.

Dust / Dirty
Spread out / Remove a mat
Snow

Change the presence timer settings to shorter

Connector not connected correctly

Incorrect power supply voltage

Adjust the detection pattern.

10. TROUBLESHOOTING

11. TECHNICAL SPECIFICATIONS

Please note that specifications are changed without notice.

0

/ +5

R4

R1

Normal / Snow

4 Frequencies

2s / 30s / 60s /

Wide / Narrow

Installation Height

Sensitivity adjustment

3.0m

Available

Presence Timer

Depth adjustment

Angle

Row

Width adjustment

Monitor mode

Frequency

Model Name

3H-IR14

AC12V 1.3VAMax
AC24V 1.5VAMax
DC12V 65mAMax
DC24V 35mAMax

Standby

(Green)

Detecting

(Red)

Door movement is detected (Orange)
Waiting for reset

(Fast flashing Orange)

Reflection Diagnostics (Flashing Red and Green)

Supply Voltage

Power
Consumption

Output

AC/DC12

24V

10% 50/60Hz

S : Silver , BL : Black

Output Holding
Time

LED Indicator

Operating
Temperature

Weight

Color

Approx 180g

-20

+60

Relay Contact1c
DC50V 0.1A Resistance load
Fail safe

Approx 0.5s

12. EXTERNAL DIMENSIONS

[mm]

< Disclaimer >
The manufacturer cannot be held responsible for
below.
1. Misinterpretation of the installation instructions,
miss connection, negligence, sensor modification and
inappropriate installation.
2. Damage caused by inappropriate transportation.
3. Accidents or damages caused by fire, pollution,
abnormal voltage, earthquake, thunderstorm, wind,
floods and other acts of providence.
4. Losses of business profits, business interruptions,
business information losses and other financial losses
caused by using the sensor or malfunction of the
sensor.
5. Amount of compensation beyond selling price in all
cases.

Adjust the monitoring mode

Mounting portion is distorted

Adjust the monitoring mode footprints being left in fresh snow

Active Infrared Reflection

Detection Method

3. If the sensor detects even
though no one is in the
detection area, please
decrease the sensitivity.

1. Please set the sensitivity suitable for the mounting height.

Sensitivity

L

M

H

Please adjust the sensitivity that is appropriate to the operation.

Area mask

3. Width adjustment

6. ADJUSTING DETECTION PATTERN

You can adjust the detection width by turning Area Mask with a screwdriver.

2. Depth adjustment

1. Angle adjustment

The detection range will vary depending on installation environment, object detected and settings etc (clothes and floor material and
sensitivity adjustment)

Delete or add rows of detection

4. DIP SWITCH SETTINGS

Ensure that the inner row of detection does not detect door movement

[m]
0

1.0

2.0

3.0

0.5

1.5

2.5

1.0 0.5

1.5

2.0

0 0.5 1.0 1.5 2.0

Wide

[m]
0

1.0

2.0

3.0

0.5

1.5

2.5

1.0 0.5

1.5

2.0

0 0.5 1.0 1.5 2.0

Narrow

Narrow

0

0.5

1.0

1.5

2.0

2.5

3.0

0

0.5

1.0

1.5

2.0

2.5

m

[+5

]

After installation and adjusting various settings, please check whether the detection range and sensitivity is suitable for
operation. If it is difficult to detect or false activations occur, please re-adjust the detection range and sensitivity settings.

8. VERIFICATION OF OPERATION

0

0.5

1.0

1.5

2.0

2.5

m

0

0.5

1.0

1.5

2.0

2.5

3.0

[0

]

The table below is an estimation.

H

L

H

L

Wide

If Self-Monitoring determines that the sensor has malfunctioned, the relay
output will cause the door to open, and the Green/Red LED blinks .
In this case, please replace the sensor immediately. OFF / ON of Self-
Monitoring can be set with DIP switch.

Relay output waveform in case of not normal

Make

Break

12 s

12 s

60 s

1 cycle

LED Indicator Flashing red and green

9. SELF-MONITORINNG

OFF / ON

Self-Monitoring

4 Rows ON

3 Rows ON

2 Rows ON

1 Rows ON

26 Dublin Street (2nd Floor), Carlow, Ireland

URL: http://www.hotron.com

Fax:

+353-(0)59-9140543

Phone: +353-(0)59-9140345

1-11-26 Hyakunin-Cho, Shinjuku-Ku, Tokyo, Japan

URL: http://www.hotron.com

Fax:

+81-(0)3-5330-9222

Phone: +81-(0)3-5330-9221

Manufacturer
HOTRON CO.,LTD.

SALES Europe
Hotron Ireland Ltd.

28.5

15

75

(Standard Mounting Pitch)

35

10

210

CAUTION

2.0 

2.5

2.5 

3.0

L

 M

M

 H

Estimated

sensitivity

Height

[m]

Reviews: