Specification Revised 11/05

420491

RB790WK/CK/BK – Hotpoint 30" Free-Standing Electric Range 

Dimensions (in inches)

Listed by 

Underwriters 

Laboratories

26-3/8*

46-3/8

1/4

29-7/8

46-1/2

CENTER LINE

2-1/4

7-1/2

7-1/2

7

5

2-1/4

3-1/2

REAR

WALL

25-7/16

46-1/8

1/4

29-7/8

45-1/8

CENTER LINE

2-1/4

7-1/2

7-1/2

7

5

2-1/4

3-1/2

REAR

WALL

Note: 

Check local codes for required breaker size.

Effective January 1, 1996, the National Electrical Code requires 

that new construction (not existing) utilize a 4-conductor 

connection to an electric range. 

Note: 

30" Electric Ranges conform to U.L. requirements for 0" 

spacing from walls below countertops. Allow 1-1/2" spacing 

from the side of the range to adjacent vertical walls above the 

cooktop surface.

Receptacle Locations: 

Locally approved flexible service cord 

or conduit must be used because terminals are not accessible 

after range installation. See shaded area in drawing for location 

of electrical outlet box. Recommended outlet locations allow 

range to be installed directly against rear wall.

Installation Information:

 Before installing, consult installation 

instructions packed with product for current dimensional data. 

 

 

KW Rating

  240V

 

10.5

 

208V

 

7.9

Breaker Size

 

40 Amps

All Hotpoint ranges are equipped 

with an Anti-Tip device. The 

installation of this device is an 

important, required step in the 

installation of the range.

* Dimension from wall to front of closed oven door. 

Dimension from wall to the front of closed oven  

door handle is 28-1/2".

†The range may be placed with

0" clearance (flush) at the back  

wall and side walls if the range  

side trims extend beyond the  

cabinet fronts at least 1/4".

Self-Clean models only 

R