Hotpoint G640SK Operating Instructions Manual Download Page 7

GB

7

S

S

A

R

 

G640SW

G640SX

G640SK

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

20

17

25

28-30

20

35

37

25

45

Rapid (R)

Semi Rapid (S)

Auxiliary (A)

Supply 

pressures

Burner

Diameter

(mm)

 Thermal Power

kW (p.c.s.*)

94

69

46

3.00

1.90

1.00

Nominal Reduced

0.70

0.40

0.40

By-pass

1/100

(mm)

39

28

28

Nozzle

1/100

(mm)

Flow*

g/h

***

87

70

52

Nozzle

1/100

(mm)

Flow*

l/h

128

104

76

286

181

95

218

138

73

**
214

136

71

At 15°C and 1013,25 mbar - dry gas

** 

Propane 

P.C.S. = 50.37 MJ/Kg

*** 

Butane  

P.C.S. = 49.47 MJ/Kg

 

Natural  

P.C.S. = 37.78 MJ/m

3

Burner and nozzle specifications

Liquid Gas

Natural Gas

Table 1

7,80 (567 g/h - G30) (557 g/h - G31)

G640SK

G640SX

G640SW

II2H3+

Gas section

Rated power (kW)

Class

Model

Electric section

220-240V~ 50/60Hz

Voltage and frequency

(1)

Power (W)

0,6

The values in g/h refer to the capacities with liquid gas (Butane, Propane).

(1)

Summary of Contents for G640SK

Page 1: ...ntents Operating Instructions 1 Warnings 2 Description of the appliance 3 Installation 4 Start up and use 8 Precautions and tips 8 Maintenance and care 9 Troubleshooting 9 Product Guarantee and Repair...

Page 2: ...nce Cleaning and user maintenance shall not be made by children without supervision WARNING Unattendedcookingonahobwithfator oil can be dangerous and may result in fire NEVER try to extinguish a fire...

Page 3: ...AS BURNERS 5 SAFETY DEVICES GASBURNERSdifferinsizeandpower Usethediameterofthecookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust size of the flame GASBURN...

Page 4: ...e roomscontainingLPGcylindersmustalsobeequippedwithventstoallow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in r...

Page 5: ...or orcolouredGreen or Green Yellow ConnecttheBrownwiretotheterminalmarked L orcolouredRedorBrown Connect the Blue wire to the terminal marked N or coloured Black or Blue FAILURE TO OBSERVE THE ACCIDEN...

Page 6: ...5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid gas the regulation screw must be fastened as tightly as p...

Page 7: ...g h 87 70 52 Nozzle 1 100 mm Flow l h 128 104 76 286 181 95 218 138 73 214 136 71 At 15 C and 1013 25 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m3 Burner...

Page 8: ...installing the hob follow the instructions provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the ser...

Page 9: ...correctly in the respective housings When replacing the grids make sure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thor...

Page 10: ...of Ireland The guarantee does not cover Damageresultingfromtransportation improperuse neglectorinterference or as a result of improper installation Replacement of any consumable item or accessory Thes...

Page 11: ...GB 11...

Page 12: ...12 GB 195125916 03 07 2015 XEROX FABRIANO Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoint co uk...

Reviews: