Gas Connection
Pressure test point
Aeration adjustment
Electrical Connection
Rp
1
/
4
(
1
/
4
” BSP female)
Burner injector
None
230-240V ac. 50Hz Heat resistant PVC 85oC 0.75mm2 Flexible
cord.
Model Numbers W810, BG05
These models are set to burn NATURAL GAS (G20) at 20mbar.
They can also be converted to burn BUTANE GAS (G30) at 28mbar or PROPANE
GAS (G31) at 37mbar using the conversion kit included.
Gas Category II
2H3+
(GB,IE)
Technical Data
BURNER
HEAT INPUT
INJECTOR
Natural Gas
Front Left
Rear Right
and Rear Left
Front Right
3.0 kW
2.0 kW
1.15kW
130
105
80
HEAT INPUT
INJECTOR
LPG
3.0 kW
2.0 kW
1.15kW
92
72
55
FP087-01 HP Gas Hob (BG05) 12/09/2001 4:59 pm Page 10