EN
15
Technical data
Model
AQ83L 29
Dimen-
sions
width 59.5 cm
height 85 cm
depth 58 cm
Capacity
from 1 to 8 kg
Electrical
connec-
tions
please refer to the technical
data plate fixed to the machine
Water con-
nections
maximum pressure
1 MPa (10 bar)
minimum pressure
0.05 MPa (0.5 bar)
drum capacity 58 litres
Spin speed
up to 1200 rotations per
minute
Test wash
cycles in
accordan-
ce with
directives
1061/2010
and
1015/2010
Programme
;
Cotton standard 60°C.
Programme
;
Cotton standard 40°C.
This appliance conforms to
the following EC Directives:
- 2004/108/EC (Electromagne-
tic Compatibility)
- 2006/95/EC (Low Voltage)
- 2012/19/EU
Connecting the drain hose
Connect the drain
hose to drain duct
piping or a wall drain
located between 65
and 100 cm above
the floor, making sure
it is not bent at all.
Alternatively, rest the
drain hose on the
side of a washbasin
or bathtub, fastening
the duct supplied to
the tap
(see figure).
The free end of the
hose should not be
underwater.
!
We advise against the use of hose
extensions; if it is absolutely necessary, the
extension must have the same diameter as the
original hose and must not exceed 150 cm in
length.
Electrical connections
Before plugging the appliance into the
electricity socket, make sure that:
• the socket is earthed and complies with all
applicable laws;
• the socket is able to withstand the maximum
power load of the appliance as indicated in
the Technical data table
(see opposite);
• the power supply voltage falls within the
values indicated in the Technical data table
(see opposite);
• the socket is compatible with the plug of the
appliance. If this is not the case, have the
socket or the plug replaced.
!
The machine must not be installed outdoors,
even in covered areas. It is extremely
dangerous to leave the appliance exposed to
rain, storms and other weather conditions.
!
The mains socket must remain within easy
reach after the washing machine has been
installed.
!
Do not use extension cords or multiple
sockets.
!
The cable should not be bent or compressed.
!
The power supply cable and plug must only
be replaced by authorised technicians.
Warning! The company shall not be held
responsible in the event that these regulations
are not respected.
65 - 100 cm