background image

 

Smart Wifi Thermostat 

                                                                                             

Reference No.:HTW-WF06 Series 

 

                                                         

 

- 2 -

                                                                            Version 2018-1.0                                                                                             

 
 

Power Supply 

95~240Vac, 50/60Hz 

Sensor 

NTC3950, 10K 

Current Load 

3A(-3A, -NV application) 

Temperature Accuracy 

±

0.5°C or 

±

1

 

16A(-16A application) 

Set-Point Range 

5~35°C 

Storage Temp. 

-5 ~ 45 °C 

Display Temp. Range 

5 ~ 99°C 

Power Consumption 

< 1.5W 

Timing Error   

< 1% 

Housing Material 

PC +ABS ( Fireproof) 

Installation Box 

EU or Standard Electric Box 

Wires on Terminals 

Wire 2 x 1.5 mm

2

 or 1 x 2.5 mm

2

 

Protection Class 

IP20 

Operating Buttons 

Capacitive Touch Buttons 

 
 
 
 
 
 
 
 
 
 
 
 

 

Make sure the power is OFF! Try turning ON your heating/cooling system by changing the temperature. If 
you can’t get the system to turn ON in 5 minutes, you’ll know the power is OFF. 

 

Take off the installation faceplate by rotating and gently pulling, then connect voltage supply/load 
output/external sensor(if with) wires respectively to appropriate terminals. 

 

Fix the installation plate onto the electric junction box with screws packed in the box. 

 

Fasten the thermostat display part and the installation faceplate through the groove.(Installation process 
completed) 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING:      RISK  OF  ELECTRICAL  SHOCK.

  Disconnect  power  supply  before  making  electrical  connection.  Contact 

with  components  carrying  hazardous  voltage  can  cause  electrical  shock  and  may  result  in  severe  personal  injury  or 

death. 

Dimensions and Display 

Specification 

Installation 

Summary of Contents for HTW-WF01 Series

Page 1: ...ch Poland simplified Chinese traditional Chinese Holland Portuguese Vietnamese Arabic Korean Snap In Easy Installation Fit for EU Standard Junction Electric Box Easily Work with Amazon Alexa Google As...

Page 2: ...ng system by changing the temperature If you can t get the system to turn ON in 5 minutes you ll know the power is OFF Take off the installation faceplate by rotating and gently pulling then connect v...

Page 3: ...etc Increase or decrease parameters by using these icons Press once more to confirm and switch to next relevant parameter setting 3 Touch the icon again to set the weekday schedule settings appear 1 2...

Page 4: ...emperature OU External sensor to control or limit the temperature Al internal sensor to control temperature and external sensor to limit the floor temperature Notes Please make sure configure the righ...

Page 5: ...ion and type in your phone No or email fig 2 3 then you may get a verification code Type in your password and con rm fig 2 4 to complete your registration If you already have an account please just lo...

Page 6: ...t can not be connected as above steps please try this AP mode connection process On the thermostat During power off status press and hold the arrow icon for 8 sec until the connecting icon appears on...

Page 7: ...Thermostat runs in Manual Mode Thermostat runs in Programmable Mode When thermostat runs in programmable mode click the schedule setting fig 5 1 to switch to the schedule page fig 5 2 where you can s...

Page 8: ...hod 1 Click Share with Familay as fig 4 4 Method 2 Click Profile Sent Add Switch on the device Share with New Member Type in the telephone number you would like to share with Method 3 Home page of the...

Page 9: ...k if the terminals between LCD panel and Relay Power Module is loosen 2 Without output but display works Use a new LCD panel or new Relay Power Module for Replacement 3 Room Temp on display is not cor...

Reviews: