To activate the Summer Mode, simply follow these steps:
1. Set the temperature control to 80°F (26°C) if desired to prevent the
heater from turning on during cooler times.
2. On the control panel press the MODE (
or
) button until TOOLS is displayed. Then
press the
(+)
button to enter the TOOLS
submenus. Press the MODE (
or
)
button in the TOOLS submenu until SUMMR
is displayed on the screen. Press the
(+)
button to activate the
Summer Timer mode. The Moon & Stars icon is on when in Summer
Timer Mode.
The Summer Mode must be deactivated when cooler temperatures
return. To do this, simply follow step 3.
3. To shut the Summer Mode off, press the MODE (
or
) button
until TOOLS is displayed. Then press the
(+)
button to enter
the TOOLS submenus. Press the MODE (
or
) button in
the TOOLS submenu until SUMMR is displayed on the screen.
Press the
(-)
button to deactivate.
SLEEP MODE
(NON CIRCULATION PUMP MODELS ONLY)
The Sleep Mode operation is a feature that minimizes pump operation
during quiet evening hours. For example, if Filter Cycle 1 (F1) is set to
activate at 8:00 a.m., by default, Filter Cycle 2 (F2) will activate at 8:00
p.m. (12 hours later). During 8:00 p.m. to 8:00 a.m., if the spa should call
for heat, the pump and heater will activate to heat the spa under normal
temperature demand. However, when in Sleep Mode, should the spa
call for heat, the pump and heater will be suspended after Filter Cycle
2 (F2) until the activation of Filter Cycle 1 (F1), at 8:00 a.m. to minimize
pump activation during quiet evening hours.
Important:
Power-up of the spa starts the F1 sequence. In order for the
sleep mode to work in the evening hours, the spa must be powered up
in the early morning hours. The Sleep Mode will always be active the
6-12 hours between the end of (F2) and the beginning of (F1) depending
on how the filter cycle program is set.
Note:
If temperature drops below 80º F (27º C), heater will automatically
activate to prevent spa from freezing.
To activate Sleep Mode feature:
A. Press the MODE (
or
) button until the
TOOLS screen is displayed.
B. Press the
(+)
button to enter the TOOLS
submenus.
C. Press the MODE (
or
) button until ECON is displayed.
D. Press the
(+)
button to activate Sleep Mode. Moon & Stars icon will
appear on the screen of the control panel, indicating this feature
has been activated.
To deactivate this feature, simply repeat steps A-C then press the
(-)
button.
FILTER CYCLES
(NON CIRCULATION PUMP MODELS ONLY)
When the spa is first powered up, the automatic filter cycle will wait
10 minutes before starting. Your spa will automatically turn the first
filter cycle on for 60 minutes on low speed. The second filter cycle will
activate for 30 minutes, 12 hours later. The filter cycle icon, F1 or F2 will
be displayed in the control panel during the filter cycle.
NOTE:
The optional
FRESHWATER
III ozone system only works during
the filter cycle.
To modify the length of either filter cycle:
A. Press the MODE (
or
) button until the
TOOLS menu is displayed.
B. Press the
(+)
button to enter the TOOLS
submenus.
C. Press the MODE (
or
) button until
FILT1 or FILT2 is displayed.
D. Press the
(+)
button to enter FILT1 or
FILT2. F1 or F2 icon will flash.
E. Using the
(+)
or the
(-)
button, adjust the desired filter cycle time,
from 0 to 6 hours.
The filter cycle will activate the jet pump on low speed for the entire
cycle. When activated, the filter cycle icon on the display is turned on.
If the temperature exceeds the set point by three degrees F for more
than three hours, the system will cancel the filter cycle for the remaining
filter cycle time. Should the temperature cool down to 1.5 degrees F
(1 degree C) below the set point before the end of the cycle, the cycle
will resume for the rest of the time. Should you use the spa during the
filter cycle by placing the jet pump on high speed, the Filter icon and
Jets icon will be on. Once the jet pump has been shut off, a ten minute
tranquil mode begins (Filter & Jet icons are off during tranquil mode
while F1 or F2 remain lit). The Filter and Jet icons will come back on
once the tranquil mode ends if the filter cycle timer is still on.
BRIGHTNESS - LCD
If you would like to change the brightness of the Control Panel screen:
A. Press the MODE (
or
) button until the
TOOLS menu is displayed.
B. Press the
(+)
button to enter the TOOLS
submenus.
C. Press the MODE (
or
) button until LCD is displayed.
D. Press the
(+)
button to enter into the LCD menu.
E. Using the
(+)
or the
(-)
button, adjust the desired screen brightness.
AUDIO MENU (OPTIONAL)
The following applies to spas that have an optional wireless audio
system installed:
When the wireless audio system has been installed on the spa, the
control panel can be used to control the audio system. The following
information demonstrates how to navigate the music menu by using the
spa’s control panel.
AUDIO MENU
Once the music system is installed, an AUDIO menu will be accessible
on the control panel screen.
To access the menu, press the MODE (
or
) button until AUDIO is
displayed.
BASIC CONTROL PANEL OPERATION
1. To enter into a sub-menu press the
(+)
button.
2. To move to the next menu press the MODE (
) button
3. To exit from any sub-menu, press MODE
(
or
) button as many times as
necessary until EXIT is displayed then
press the
(+)
button to exit that sub-menu.
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
Page 16
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
POWER
Operating Instructions