Host HIV10GH1P116 Product Instruction Manual Download Page 7

or eliminate the problem:

Use an extension cord to increase the distance between the inverter and the TV, antenna and
cables.

Adjust the orientation of the inverter, television, antenna and cables.

Maximize TV signal strength by using a better antenna and use shielded antenna cable where
possible.

Try a different TV. Different models of televisions vary considerably in their susceptibility to inverter.

5. Troubleshooting

PROBLEM: AC product will not operate

Possible Cause

Suggested solution

Battery is defective.

Check battery and replace if
required.

Inverter has been connected
with reverse DC input polarity.

Check connection to battery. Probable inverter damage
has occurred. Have unit repaired(not covered by warranty)

Loose cable connections.

Check cables and connections. Tightens required

PROBLEM: Inverter will run some small loads, but not large ones.

Possible Cause

Suggested solution

Voltage drop across DC cables. Shorten cables or use heavier cables.

PROBLEM: Measured inverter output is too low.

Possible Cause

Suggested solution

Standard ”average-reading” AC
voltmeter used to measure
output voltage, resulting in an
apparent reading 5 to 15 volts
too low.

Inverter’s “modified sine wave” output requires “true RM”
voltmeter, such as Fluke 87 series millimeters for accurate
measurement.

Battery voltage is too low.

Recharge battery.

PROBLEM: Alarm is sounding.

Possible Cause

Suggested solution

Low voltage shut down or
thermal

shutdown

has

occurred.

Shorten cables or use heavier cables. Recharge battery.
Allow unit to cool. Improve air circulation around unit.
Reduce load if continuous operation is required.

PROBLEM: Battery run time is less than expected.

Possible Cause

Suggested solution

AC product power consumption
is higher than rate.

Use a larger battery to make up for increased power
requirement

Battery is old or defective

Replace battery

Summary of Contents for HIV10GH1P116

Page 1: ...Product Instruction Manual DC TO AC Power Inverter TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTION MANUAL...

Page 2: ...ION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FURTURE REFERENCE TABLE OF CONTENTS 1 Important Safety Information 2 Introduction 3 Installation Guidelines 4 Using the inver...

Page 3: ...hazard Do not use the inverter in the presence of flammable fumes or gases such as in the bilge of a gasoline powered boat or near propane tanks Do not use the inverter in an enclosure containing auto...

Page 4: ...g vents or other heat producing equipment Well ventilated Allow at least 2 inches 5cm clearance above and on all sides of the unit for proper cooling Safe Do not install inverter in a compartment with...

Page 5: ...urge power occasionally some products rated less than the rated continuous output power may exceed its surge capabilities and trigger its safety overload shutdown feature If this problem occurs when a...

Page 6: ...utomatically shut down See Section 4 Battery Operating Time Operating time will vary depending on the charge level of the battery its capacity and the power level drawn by the particular AC load When...

Page 7: ...small loads but not large ones Possible Cause Suggested solution Voltage drop across DC cables Shorten cables or use heavier cables PROBLEM Measured inverter output is too low Possible Cause Suggeste...

Page 8: ...is discharged alarm is sounding Recharge Battery Inverter has overheated due to poor ventilation and has caused over temperature shutdown Switch inverter OFF and allow to cool for 15 minutes Clear bl...

Reviews: