19
DN08.05.20Rev 00 www.hosseven.com.tr
• If the gas inlet pressure is less than 20 mbar, it should be brought to 20 mbar.
To increase the gas inlet pressure, regulator in the gas line should be used. Pressure
increase and decrease cannot be made on the radiant device.
• If the gas outlet pressure (injector pressure) is different from the value
indicated in the table, we can increase or decrease the gas outlet pressure from the
regulating regulator.
5.1.
Operation of the Device
1. Make sure that gas and electrical connections comply with the rules specified
in the manufacturer's user manual.
2. Open the gas through the gas valve.
3. Make sure that the gas pressure is set correctly.
4. Turn on the heater electrical connection.
5. Press the on / off button on the remote control once. (you can also operate
the device with the green button next to the device)
6. The device will continue to burn in Stage 1 after burning has occurred. You
can get the desired level from the remote by pressing (+ and -) keys.
7. To switch off the device, you can switch the device off by pressing the on / off
button.
8. If the device did not work, switch off the device.
9. Wait about 5 seconds before turning it back on. If the burner does not light
after firing the intermittent spark plug 3 times, find the cause from the fault finding
table given in the manual. If you can not solve, call the company service.
5.2.
Device Shutdown
1. If you are temporarily closing, just turn it OFF with the REMOTE CONTROL
2. If you are closing permanently, turn off the electricity and gas valve.