47
J. Body-Prefinal
RH1-AAC(-HD)
K-0, K-1, L-0, L-5, M-5, M-6, M-7, N-5, N-6, P-5, P-6, P-7, Q-5
6
7
1
M-6 and earlier for RH1-AAC
L-5 and earlier for RH1-AAC-HD
The santoprene light socket was changed to
a porcelain lampholder at M-7 for FH1-AAC
and at M-5 for FH2-AAC-HD. This change
is non-interchangeable. If the light socket is
not operating on a unit with a santoprene
light socket, Hoshizaki recommends
replacement with HS-3554.
Note:
Parts 4, 5 and 5a are not included in
HS-3554; they are shown for reference only.
HS1
4
5a
5
HS2
HS1a
HS2a
5a
5
2a
2
3a
3
8
M-7 and later for RH1-AAC
M-5 and later for RH1-AAC-HD
4
9
10