![Hoshizaki Modular Cubelet Serenity Series Service Manual Download Page 35](http://html1.mh-extra.com/html/hoshizaki/modular-cubelet-serenity-series/modular-cubelet-serenity-series_service-manual_2164852035.webp)
35
Shutdown
1. Bin Control 1 (infrared sensor)
See "II.D. Bin Control Check."
a) Dirty lens.
b) Defective.
c) Control board (no power to IS).
2. BC2 (Mechanical Backup) See
"II.D. Bin Control Check."
a) Defective.
3. Control Board
a) Control board dip switches set incorrectly.
b) In alarm.
c) Defective.
Drain Cycle
1. Drain Valve
a) Screen or orifice clogged.
b) Defective.
2. Control Board
a) Defective.