background image

Models
KMS-1402MLJ

Including

Condensing Unit Models
SRK-15J/3

Modular Crescent Cuber

Serenity Series

Instruction Manual

Issued: 1-22-2018
Revised: 3-6-2018

hoshizakiamerica.com

Summary of Contents for KMS-1402MLJ

Page 1: ...Models KMS 1402MLJ Including Condensing Unit Models SRK 15J 3 Modular Crescent Cuber Serenity Series Instruction Manual Issued 1 22 2018 Revised 3 6 2018 hoshizakiamerica com...

Page 2: ...per installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist...

Page 3: ...densing Unit 19 1 Setup 19 2 Line Set 19 3 Line Set Installation 20 F Electrical Connection 22 G Water Supply and Drain Connections 25 H Final Checklist 27 I Startup 28 III Maintenance 30 A Maintenanc...

Page 4: ...Move the control switch to the OFF position and turn off the power supply to the remote condensing unit before servicing Place the icemaker disconnect if applicable in the OFF position Lockout Tagout...

Page 5: ...e for electrical specifications Failure to use an independent power supply of proper capacity can result in a tripped breaker blown fuse damage to existing wiring or component failure This could lead...

Page 6: ...sure HI 467PSI LO 230PSI Total Refrigerant Charge 404A Total Refrigerant Charge with Hoshizaki Remote Condensing Unit SRK 15J 3 16 LB 5 OZ 2 SRK 15J 3 Model Number SRK 15J SRK 15J3 AC Supply Voltage 2...

Page 7: ...Allow 6 15 cm clearance at rear sides and top for proper air circulation and ease of maintenance and or service should they be required The ice storage bin opening must match the bottom opening as in...

Page 8: ...8 2 SRK 15J 3 Unit mm in Note Legs are included with remote condensing unit Leg height is 380 mm 14 96 in Top Side Front...

Page 9: ...emaker NOTICE This icemaker is not intended for outdoor use Normal operating ambient temperature must be within 45 F to 100 F 7 C to 38 C Normal operating water temperature must be within 45 F to 90 F...

Page 10: ...sing unit and the icemaker is greater than 20 feet not to exceed 33 feet an S oil trap 5 8 OD copper tubing must be installed in the suction line The S oil trap must be located halfway between the ice...

Page 11: ...e film after the icemaker cools Check that the refrigerant lines do not rub or touch lines or other surfaces This icemaker can be installed on a dispenser unit or storage bin 30 wide or wider For opti...

Page 12: ...II D 2 Water Tank Removal Fig 4 Top Panel Right Side Panel Louver Panel Front Panel Remote Condensing Unit Right Side Panel Fig 3 Top Panel Front Panel Insulation Panel Icemaker 2 Remote Condensing Un...

Page 13: ...4 adjustable legs provided bin accessory to the bottom of the storage bin 2 Position the dispenser unit storage bin in its permanent location 3a Dispenser Unit Install the dispenser unit adapter kit...

Page 14: ...s Seal the outer perimeter of the icemaker to the dispenser unit with RTV 748 sealant provided or equivalent 5b Storage Bin Secure the icemaker to the storage bin using the 2 mounting brackets and the...

Page 15: ...ough the back of the icemaker If care is not taken when removing the water tank the bin control cable could be severed Pump Suction Hose Drain Pipe Water Tank Drain Hose Float Connection Hose Splash C...

Page 16: ...uivalent Otherwise water leakage may occur which could result in a slip hazard and costly water damage Contact points between the dispenser unit and the dispenser unit adapter kit Contact points betwe...

Page 17: ...using the 2 thumbscrews from the accessory bag Route the bin control cable from the outer corner of the bin control up through the gap in the extension bracket 4 Using the 2 thumbscrews removed in st...

Page 18: ...ge the bin control Dispenser Unit Slide the bin control assembly all the way back until the switch mount is flush with the dispenser unit bin wall Storage Bin Slide the bin control assembly all the wa...

Page 19: ...e to equipment The maximum line set length is 66 feet and no refrigerant charge adjustment is necessary NOTICE Do not exceed maximum line set length Line Set Size and Length for SRK 15J 3 Remote Conde...

Page 20: ...to allow the icemaker to be pulled out for service See Fig 14 Note The service loop is not considered an oil trap 2 Remove any extra line set length 3 NOTICE Before brazing remove the Schrader valve...

Page 21: ...rt is available at 1 800 233 1940 for recommendations Fig 14 Suction Line S Oil Trap Max 33 Feet Max 16 5 Feet Max 16 5 Feet Remote Condensing Unit with compressor Bin Icemaker Service Loop Max 10 Fee...

Page 22: ...to meet these code requirements could result in death electric shock serious injury fire or damage The remote condensing unit requires an independent power supply of proper capacity See the nameplate...

Page 23: ...the transformer s voltage tap switch must be positioned to match incoming voltage at startup NOTICE On three phase models connect the highest incoming voltage supply stinger leg to the power wire ded...

Page 24: ...gend GND ground HGV hot gas valve CB control board LLV liquid line valve Wire Color Code BK black BR brown GR green P pink V violet W white KMS Icemaker Fuse 10A Icemaker Remote Condensing Unit Wire B...

Page 25: ...be required in some areas External filters strainers or softeners may be required depending on water quality Contact your local Hoshizaki distributor for recommendations Water supply pressure should b...

Page 26: ...is 5 8 OD hard tube The condensation drain line can be connected to the icemaker drain line or can be run separately Fig 17 KMS 1402MLJ Icemaker Water Supply Inlet 1 2 FPT Icemaker Water Supply Line S...

Page 27: ...et all national state and local code and regulation requirements 8 Has the power supply voltage been checked or tested against the nameplate rating Has a proper ground been installed to the remote con...

Page 28: ...k to fill with water and the icemaker to operate for a total of 10 minutes 5 After 10 minutes of operation confirm bin control operation Remove the front panel then press and hold the bin control s ac...

Page 29: ...the ICE position 16 Replace the front panel in its correct position 17 Turn on the power supply to start the automatic icemaking process Pump Suction Hose Drain Pipe Water Tank Drain Hose Float Conne...

Page 30: ...iance s environment and local sanitation regulations Maintenance Schedule Frequency Area Task Daily Scoop Clean the ice scoop using a neutral cleaner Rinse thoroughly after cleaning Monthly External W...

Page 31: ...prevent damage to the water pump seal do not operate the icemaker with the control switch in the SERVICE position when the water tank is empty 1 Cleaning Procedure 1 Dilute 22 fl oz 650 ml of Hoshizak...

Page 32: ...eir correct positions 12 Turn on the power supply to start the washing process 13 Turn off the power supply after 30 minutes Remove the front panel 14 Move the service switch to the DRAIN position 15...

Page 33: ...start the sanitizing process 7 Turn off the power supply after 15 minutes Remove the front panel 8 Move the service switch to the DRAIN position 9 Replace the front panel in its correct position then...

Page 34: ...l board should be on 6 Once LED 1 and 2 on the control board energize the order of the LEDs from the outer edge of the control board is 1 4 3 2 close the inlet water supply line shut off valve and ope...

Page 35: ...pump connector 20 Close the inlet water supply line drain valve 21 Remove all ice from the dispenser unit storage bin and clean the dispenser unit storage bin liner using a neutral cleaner Rinse thoro...

Page 36: ...sal The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service...

Page 37: ...37 618 Hwy 74 South Peachtree City GA 30269 USA P 770 487 2331 F 770 487 3360 hoshizakiamerica com 1A5034 010...