53
VIII. Technical Information
We reserve the right to make changes in specifications and design without prior notice.
A. Specification and Performance Data
Pressure data is recorded at 5 min. into freezing cycle. The data not in bold
should be used for reference only.
1. KMH-2100SWJ3
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
10.0 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2430 (2.92)
2480 (2.89)
WATER gal./24HR (gal./100 lbs.)
300 (15.0)
450 (21.9)
WATER COOLED CONDENSER
1830 (92)
1085 (53)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
42.6 lbs. (19.3 kg) 2160pcs.
BIN CONTROL
Thermostatic
REFRIGERANT CHARGE
TOTAL R404A, 3 lb. 1.4 oz. (1400g)
Performance Data Sheet
70/21
2060
934
2042
926
1921
871
80/27
2046
928
2019
916
1844
836
90/32
2042
926
2000
907
1845
837
lbs./day kg./day
100/38
1985
900
1963
891
1702
772
70/21
80/27
90/32
watts
100/38
70/21
1536
5.81
1710
6.47
2236
8.46
80/27
1669
6.32
1939
7.34
2625
9.94
90/32
1710
6.47
2130
8.06
2759
10.45
gal./day m
3
/day
100/38
2095
7.93
2278
8.62
3338
12.63
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
247
17.4
250
17.6
260
18.3
80/27
249
17.5
254
17.8
267
18.8
90/32
250
17.6
257
18.1
269
18.9
PSIG kg/cm
2
G
100/38
254
17.9
260
18.3
280
19.7
70/21
50
3.5
50
3.5
52
3.7
80/27
50
3.5
50
3.5
53
3.7
90/32
50
3.5
50
3.5
53
3.7
PSIG kg/cm
2
G
100/38
51
3.6
51
3.6
55
3.9
22,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
129 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2480
2465
2507
2469
2446
2522
2465
2430
2493
2495
2445
2550
APPROXIMATE WATER CONSUMPTION
PER 24 HR.
FREEZING CYCLE TIME
27
27
27
27
27
27
27
27
27
27
27
27
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.0
3.6
3.5
3.7
3.1
3.3
3.6
2.6
2.7
3.2
2.6
2.8
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205