56
[2] Remove the water from the potable water supply line:
1) Remove the Front Panel. (Except water-cooled model)
2) Move the Control Switch, on the Control Box, to the “OFF” position.
3) Wait 3 minutes.
4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water
Supply Line Drain Valve.
5) Allow the line to drain by gravity.
6) Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve.
7) Move the Control Switch to the “ICE” position.
8) Blow the potable water line out using compressed air or carbon dioxide.
[3] Drain the Potable Water Tank:
1) Turn off the power supply.
2) Move the Control Switch to the “OFF”
position.
3) Drain the Water Tank by removing the
base cover and one end of the pump
tubing. See Fig. 4.
4) Replace the removed parts in their correct
positions.
5) Remove all ice from the Storage Bin, and
clean the Storage Bin.
6) Replace the Front Panel in its correct
position.
7) Close the Drain Valve.
Fig. 4
Summary of Contents for KM-630MAF
Page 11: ...11 b KM 630MWF ...
Page 12: ...12 c KM 630MRF ...
Page 25: ...25 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 630MAF ...
Page 26: ...26 b KM 630MWF ...
Page 27: ...27 c KM 630MRF ...
Page 29: ...29 b KM 630MRF U1GMA0179608 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...