37
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-350MAJ, KM-350MWJ
OFF OFF OFF ON ON OFF ON OFF ON ON
KM-520MAJ, KM-520MWJ, KM-520MRJ
OFF OFF OFF OFF OFF OFF ON OFF ON ON
KM-660MAJ, KM-660MWJ, KM-660MRJ
OFF OFF OFF OFF OFF OFF ON OFF ON ON
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
All Models
OFF OFF OFF OFF ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time/Harvest Time During Pump-Out (3 & 4)
Harvest Time (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist (7) (Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
1
2
3
4
5
ON
S5 Dip Switch
(
Do Not Adjust)
Refill Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)
Harvest Pump Time (Harvest Assist) (6)
(Do Not Adjust)
Summary of Contents for KM-350MAJ
Page 58: ...58 7 KM 660MWJ DATA PENDING ...