4. KM-1301SWJ3
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
6.1 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1830 (3.25)
1850 (3.27)
WATER gal./24HR (gal./100 lbs.)
217 (16.0)
464 (34.1)
WATER COOLED CONDENSER
1287 (95)
743 (55)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
29.3 lbs. (13.3 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 2 lb. 2.4 oz. (975g)
Performance Data Sheet
70/21
1360
617
1359
616
1356
615
80/27
1359
616
1357
615
1354
614
90/32
1359
616
1355
615
1352
613
lbs./day kg./day
100/38
1358
616
1354
614
1350
612
70/21
80/27
90/32
watts
100/38
70/21
1206
4.57
1293
4.90
1871
7.08
80/27
1273
4.82
1408
5.33
2240
8.48
90/32
1293
4.90
1504
5.69
2240
8.48
gal./day m
3
/day
100/38
1620
6.13
1676
6.35
2916
11.04
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
251
17.6
254
17.8
256
18.0
80/27
253
17.8
257
18.1
259
18.2
90/32
254
17.8
260
18.3
263
18.5
PSIG kg/cm
2
G
100/38
254
17.9
261
18.3
265
18.6
70/21
60
4.2
60
4.2
60
4.2
80/27
60
4.2
60
4.2
61
4.3
90/32
60
4.2
60
4.2
61
4.3
PSIG kg/cm
2
G
100/38
60
4.2
60
4.2
61
4.3
20,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
113 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
2.8
2.2
2.1
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.7
3.3
3.1
3.4
2.7
2.7
3.3
2.2
2.1
29
28
29
30
29
29
30
1840
1826
1800
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
28
28
29
28
29
APPROXIMATE ELECTRIC
CONSUMPTION
1850
1844
1831
1846
1836
1820
1844
1830
1814
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205