D. Control Board Information Display
1) With unit on, press and hold the "SERVICE 1" button for 3 seconds. Display changes to
"n1".
2) Use the "SERVICE 1" and "SERVICE 2" buttons to move through the list.
3) Press the "RESET" button to view the item’s value.
4) Press the "RESET" button to return to list.
5) Display returns to normal if no buttons are touched for 20 seconds.
Control Board Information Display
No. Item
Description
History Cleared by
Pressing and Holding
SERVICE 1 and
SERVICE 2 Buttons
Simultaneously for
5 Sec. when Item Value
is Displayed?
n1 Freeze Cycle Time
During Freeze Cycle: Time since freeze cycle
started.
After Freeze Cycle: Time of previous freeze cycle.
0 to 99 min.
No
n2 Freeze Cycle Completion Rate
During Freeze Cycle: Percent of freeze cycle
completed.
After Freeze Cycle: Percent of previous freeze cycle
completed.
0 to 100%
00 = 100%
No
n3 Current Evaporator (Cube Control) Thermistor
Temperature
°C
No
n4 Current Control Board Thermistor Temperature
°C
No
n5 Water Temperature
Temperature at evaporator (cube control) thermistor
30 seconds after pump motor energized in freeze
cycle plus the water temperature correction value
(Control Board Setting 13).
"H" if Higher than 48°F
(9°C)
"L" if 48°F (9°C) or
Lower
No
n6 Current Condenser Thermistor Temperature
Not Applicable to IM-200BAC
°C
No
h1 Last Completed Freeze Cycle Time
Freeze cycles interrupted by bin control shutdown
or the "RESET" button are not recorded.
0 to 99 min.
Yes
h2 Number of Completed Freeze Cycles Since Last
Counter Reset
Counter updates every 10 freeze cycles. Freeze
cycles interrupted by bin control shutdown or the
"RESET" button are not recorded.
Displays up to 999,999
cycles. Displays two
digits at a time. For
example, 655,350 cycles
display as follows:
65>off>53>off>50>off>- -
(repeat)
Yes
h3 Total Number of Completed Freeze Cycles
Counter updates every 10 freeze cycles. Freeze
cycles interrupted by bin control shutdown or the
"RESET" button are not recorded.
No