4
2A9096-010
7) Place the new heated condensate pan on the base of the new condensate pan bracket. See Fig. 11. Note: When placing the heated
condensate pan into position, be sure that the elbow nor the new condensate drain hose make contact with the heater. See Fig. 12.
(Adjust as necessary).
New Condensate
Pan Bracket
Model Shown: UF48A
New Heated
Condensate Pan
Fig. 11
Condensate
Drain Hose
New Heated
Condensate Pan
Condensate
Drain Hose
Heater
Fig. 12
C. Wiring Instructions
If the condensate pan heater wire harness receptacle is already installed skip to step 15. Otherwise, continue to step 8.
8) Locate and remove the folded plastic sleeve to gain access to the wires and bell connectors. See Fig. 13.
Fig. 13
Nylon Tie
Folded Protective Sleeve
Bell Connectors Inside
9) Confirm the appliance is unplugged from the electrical outlet. Next, locate the power supply neutral white (W) wire. Leaving plenty of
slack, cut the power supply neutral white (W) wire.
10) Strip both ends of the power supply neutral white (W) wire cut in step 9 a 1/4" (6.35 mm) back from the ends. Place the wire
harness receptacle provided in this kit, white (W) wire and the 2 power supply neutral white (W) wires just cut and stripped, in a bell
connector provided in this kit, and tighten. See Fig. 14.
11) Next, locate the power supply black (BK) wire. Leaving plenty of slack, cut the power supply black (BK) wire.
12) Strip both ends of the power supply black (BK) wire cut in step 11 a 1/4" (6.35 mm) back from the ends. Place the wire harness
receptacle black (BK) wire and the 2 power supply black (BK) wires just cut and stripped, in a bell connector, and tighten.
Heated
Condensate Pan
Fig. 14
White
(W) Bell
Connector
Black
(BK) Bell
Connector
Appliance
Ground
Wire Harness Receptacle Ground
13) Attach and secure the wire harness receptacle ground green (GR) wire to
the appliance ground screw. See Fig. 15.
WARNING!
Make sure grounding
wires are attached and secure.
Appliance Grounding Screw
Fig. 15