1.5 Installation and assembly 

This appliance is intended for indoor use only. Be sure the location chosen has a floor 
strong enough to support the total weight of the unit and contents. For the most efficient 
operation, be sure to provide good air circulation inside and outside of the unit. 

 
INSIDE CABINET

   

The first cleaning must be made when you unpack the unit and before switching it on. 
Clean  it  with  water  and  a  mild  detergent.  When  it  is  clean  and  dry,  insert  the 
accessories in the appropriate places, for the best use of the user. 

OUTSIDE CABINET 

Be sure the unit has good air circulation around it. Avoid hot corners and locations near 
stoves and ovens. It is recommended the unit be installed no closer than 2” from any 
wall.  Place  in  a  clean  area  to  avoid  clogging  the  condenser,  which  can  cause  low 
performance and failures. 

The unit should not be installed in ambient temperatures higher than 100°F. If the 
relative  humidity  is  higher  than  60%,  condensation  may  form  around  the  door 
frame. This is not a malfunctioning of the unit

.  

1.6 Connections  

Refer  to  the  amperage  data  on    the  nameplate  and  your  local  code  or  the  National 
Electrical Code to be sure unit is connected to the proper power source. Verify correct 
incoming voltage according to the nameplate information. 

A  protected  circuit  of  the  correct  voltage  and  amperage must  be  run for  connection  of 
the power cord. Unit must be grounded and connected in accordance with NEC Article 
422 Appliances. 

 

 

 

Summary of Contents for HD-2D-59

Page 1: ...Instruction Manual Direct Draw Equipment Models HDD 1 24 S HDD 2 59 S HDD 3 69 S HDD 3 80 S HDD 4 95 S hoshizakiamerica com Issued 08 04 2018 Revised ...

Page 2: ...ber _____________________________ Serial Number _____________________________ Complete and detailed explanation of the problem WARNING Only qualified service technicians should install and service the appliance To obtain the name and phone number of your local Hoshizaki Certified Service Representative visit www hoshizaki com No installation or service should be undertaken until the technician has...

Page 3: ...7 1 1 General information 7 1 2 Transport handling unpacking location 7 1 3 Intended use and restrictions 8 1 4 Manufacturer s identification label description 8 1 5 Installation and assembly 9 1 6 Connections 9 OPERATION 10 2 1 General Information 10 2 2 Control Panel Description 10 2 3 Machine settings and programs 11 2 4 Analog Thermostat 12 2 5 Tower Installation 13 MAINTENANCE 15 3 1 General ...

Page 4: ... OFF position Unplug the appliance from electrical outlet This appliance requires an independent power supply of proper capacity See name plate for electrical specifications Failure to use an independent power supply of proper capacity can result in a tripped breaker blown fuse damage to existing wiring or component failure This could lead to heat generation or fire THE APPLIANCE MUST BE GROUNDED ...

Page 5: ... sensory or mental capabilities or lack of experience and knowledge unless they have been give supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be properly supervised around the appliance Do not climb stand or hang on the appliance or doors or allow children or animals to do so Do not climb into the appliance or allow children or a...

Page 6: ...affect performance and damage the appliance Do not allow the appliance to bear any outside weight To prevent deformation or cracks do not spray insecticide onto the plastic parts or let them come into contact with oil To avoid damage to the gasket use only the drawer handle when opening and closing To avoid damage to the top seal do not lift the appliance by the top panel or remove the top panel D...

Page 7: ...d during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written f...

Page 8: ...ANDARDS If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 1 4 Manufacturer s identification label description The nameplate is located inside the cabinet near the top front left corner Under no circumstances should the nameplate be removed from the unit The nameplate is essential to identify the particular features...

Page 9: ...ocations near stoves and ovens It is recommended the unit be installed no closer than 2 from any wall Place in a clean area to avoid clogging the condenser which can cause low performance and failures The unit should not be installed in ambient temperatures higher than 100 F If the relative humidity is higher than 60 condensation may form around the door frame This is not a malfunctioning of the u...

Page 10: ... the cabinet is critical Do not block the air outlet or the evaporator fan grill A minimum of 2 inches of space along the front back and sides is required for proper air flow 2 2 Control Panel Description Models HDD 2 59 S HDD 3 69 S HDD 3 80 S HDD 4 95 S Door to access condensing unit and control box Controller Controller Power Switch Turn On Off Appliance Lamp Switch Turn On Off The Lamp ...

Page 11: ...rams Changing the temperature setpoint on the controller The unit comes with a factory default setpoint of 32 F If setpoint needs to be changed follow the steps below Press and hold the SET button for one second You should see a flashing number Release the button Press the UP or DOWN arrows to increase or decrease the setpoint Then press the SET button to save the new setpoint Note The maximum val...

Page 12: ...tat Model HDD 1 24 Before connect the unit to the power supply verify the analog thermostat is NOT in the OFF position OFF over the yellow mark If the dial is in the OFF position the compressor will not run but the evaporator fan will still power while the analog thermostat is in the OFF position The dial of the analog thermostat is to set the temperature and this is located inside the cabinet fig...

Page 13: ...1 Locate the gaskets and bolts included in with your Tower accessories kit Place gasket over the pre drilled holes on top and place the 4 screws thru the tower base Align the tower with screws and gasket to the top as shown below while dropping the beer line s thru the hole on top of the unit Step 2 Tighten the screws using the nuts found in your tower accessories kit Step 3 Identify the WHITE HOS...

Page 14: ...14 Step 4 Introduce the WHITE HOSE CORRUGATED into the tower s HOLE Be sure that the hose hook is correctly attached into the tower hole Hose Hook ...

Page 15: ...ess steel surface Common items include peppers tomatoes and other vegetables 3 2 1 Cleaning the Condenser Coil Move the power switch to the OFF position then unplug appliance remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended every 30 60 days depending of the accumulation of dust and grease If the buildup on the coil consi...

Page 16: ...ts place slide in the unit carefully BE SURE DRAIN PIPE IS LOCATED OVER THE PAN Replace front bottom panel plug the appliance into the electrical outlet then move the power switch to the ON position 3 3 Machine disposal The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly ce...

Page 17: ...to receive assistance b Check the temperature setpoint on the controller The default setpoint is 32 F On HDD 1 24 Check the dial position The default position is 5 c Check if the compressor is running d Ensure Equipment is placed in a ventilated place and is a minimum of 2 inches from any other appliance and away from any heat source The maximum ambient temperature is 100 F e To ensure proper air ...

Reviews: