E0- probe 1 error:
This error belongs to appliance sensor
control, if this error showing on carel display, need to change
the appliance sensor fitted in the dew collector assembly.
E1- probe 2 error:
This error belongs to defrost sensor failure, if
this error displays on the carel controller display, need to
change defrost sensor fitted in evaporator fins.
Ed- defrost ended by timeout:
this error belongs to defrost
timeout, if the defrost cycle finish without reaching the
required temperature, then this alarm will displays in carel.
For all these type of errors, the values are programmed before
to the carel controller.
CAREL CONTROLER ALARMS