I. GENERAL INFORMATION
1. CONSTRUCTION
CAUTION
The height of the adjustable legs must be within
9 - 12 cm (or 15 - 18 cm for some models).
If extended too much, the legs may become
weak or the adjusters can come off, causing
unexpected injuries.
* Avoid a site where dripping is not allowed.
Especially, a side-by-side or back-to-back
installation (possibly with other manufacturer’s unit)
may cause condensation between the two units,
resulting in dripping onto the floor.
* Do not expose the unit to direct sunlight or higher
temperatures.
* Allow at least 50 cm clearance between the
front panel air inlet/outlet and the wall or other
equipment for proper air circulation. The front of
the unit should have enough space for smooth
adjustment of the cabinet temperature. If the
ambient temperature can exceed 38°C, allow at
least 10 cm clearance from the wall at the side of
the machine compartment to prevent overloading
and damaging the refrigeration circuit.
Front Panel
Front Panel
Air Outlet
Door (L)
Door (R)
Top Panel
Front Panel
Air Inlet
Power Cord
Nameplate
Leg
(or Caster)
Shelf
Window Panel
Fig. 1
Note: Attach the four legs (or casters) provided to
the mounting holes located at the bottom of
the unit.
II. INSTALLATION AND OPERATING
INSTRUCTIONS
1. LOCATION
IMPORTANT
This refrigerator/freezer is not intended for
outdoor use. Normal operating ambient
temperature should be within 5°C to 43°C (ISO
climatic class: 5).
For best operating results:
* The refrigerator/freezer should not be located
next to ovens, grills or other high heat producing
equipment.
* The location should provide a firm foundation for
the equipment.
* To adjust the height of the unit, turn the adjusters
of the adjustable legs. The unit should always be
level from side to side and back to front (levelness:
within 1°).
Fig. 3
Air Outlet
Air Inlet
Min. 50cm
2. SET UP
IMPORTANT
1. Do not tilt the unit more than 45° when
mounting the legs or casters.
2. Carry the unit by holding its bottom.
1) Cut the shipping band and remove the carton.
Fig. 2
Adjustable Leg
Adjuster
Leg Height
Longer Shorter
Fig. 4
Carton (Base)
Carton
Shipping Band
2) Take out the accessory legs or casters.