C. Location
CAUTION
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.
2. This icemaker will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the icemaker if the air temperature is going to
go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."
For best operating results:
• The icemaker should not be located next to ovens, grills, or other high heat producing
equipment.
• The location should provide a firm and level foundation for the equipment.
• Allow 6" (15 cm) clearance at rear and sides for proper air circulation and ease of
maintenance and/or service should they be required. Allow 24" (61 cm) clearance at top
to allow for removal of the auger.
D. Setup
1) Position the icemaker in the selected permanent location.
2) Attach the 4 adjustable legs provided to the bottom of the icemaker.
3) Level the icemaker in both the left-to-right and front-to-rear directions.
4) Replace the panels in their correct positions.