32
2. Removal and Replacement of Extruding Head
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical
outlet.
2) Close the water supply line shut-off valve.
3) Remove all ice from the storage bin.
4) While maintaining a hold on the door, remove the hinge stop pin from hinge (B). Pull out
the bottom of the door slightly, then gently remove the door from hinge (A). See Fig. 7.
5) Remove the top panel.
6) Remove the spout.
7) Remove the upper rear panel. See
Fig. 9.
8) Remove the clamp securing the drain
plug, then lower the drain hose into a
container. Remove the drain plug to
drain the water from the reservoir and
evaporator assembly.
9) After all of the water has drained,
replace the drain hose, drain plug,
and drain clamp in their original
positions.
10) Remove the cutter and packing.
11) Remove the allen head cap screws
securing the extruding head and
evaporator flange, then lift off.
12) Place the evaporator flange and new extruding head in place, then tighten down the
allen head cap screws.
13) Open the water supply line shut-off valve and check for water leaks. Replace the
removed parts in the reverse order of which they were removed.
14) Plug the unit back in. Move the power switch to the "ON" position.
3. Removal and Replacement of Auger
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical
outlet.
2) Close the water supply line shut-off valve.
3) Remove all ice from the storage bin.
4) While maintaining a hold on the door, remove the hinge stop pin from hinge (B). Pull out
the bottom of the door slightly, then gently remove the door from hinge (A). See Fig. 7.
5) Remove the top panel.
6) Remove the spout.
7) Remove the upper rear panel. See Fig. 9.
Spout
Extruding
Head
Packing
Upper Rear Panel
Clamp
Drain Plug
Drain Hose
Fig. 9
Cutter
Evaporator
Flange
Reservoir Hose
Evaporator
Condensate Drain Pan