Adhere to the following safety precautions whenever any type of connection is made to the module.  

  Connect the green safety (earth) ground first before making any other connections.  

  When connecting to electric circuits or pulse-initiating equipment, open their related breakers.  

Do not make connections to live power lines.    

  Make connections to the module first; then connect to the circuit to be monitored.   

  Route power wires in a safe manner in accordance with good practice and local codes. 

  Wear  proper  personal  protective  equipment  including  safety  glasses  and  insulated  gloves 

when making connections to power circuits.  

  Ensure hands, shoes, and floor are dry before making any connection to a power line.  

  Make  sure  the  unit  is  turned  OFF  before  making  connection  to  terminals.    Make  sure  all 

circuits are de-energized before making connections.  

  Before  each  use,  inspect  all  cables  for  breaks  or  cracks  in  the  insulation.    Replace 

immediately if defective.  

 

TECHNICAL SUPPORT 

 

North America: 

Tel:  317 916-4274 
Fax: 317 639-4279 
Web:    

http://www.heapg.com

  

Email:  

[email protected]

 

Europe: 

Tel:  +353-21-4321266 
Fax: +353-21-4321826 
Web:    

http://www.horner-apg.com

 

Email:  

[email protected]

 

 

 

Cscape, SmartStix and CsCAN are trademarks of Horner APG. This information is subject to change without notice. 

Summary of Contents for SmartBlock HE579THM100

Page 1: ...orted J K N T E C R S B Relative Humidity 5 to 95 Non condensing Millivolt Ranges 25mv 50mv 100mv 200mv 16 bit Resolution Operating Temperature 0 to 60 Celsius Millivolt Accuracy 0 1 Full Scale Weight 12oz 340g Accuracy Note Accuracy Specifications not guaranteed below 200 C Common Mode Range wrt field common 10VDC Max Types J K T E N Type C B Types R S A D Conversion Time 6 channels per second 1 ...

Page 2: ...e lower left grounding location into a grounded back plate Alternately a ground can be connected to the spade lug Please see Horner manual MAN0799 for details on CAN wiring CAN Network Power Port Pin Assignments Pin Signal Signal Description Direction 1 V CAN and Device Ground Black 2 CN_L CAN Data Low Blue In Out 3 SHLD Shield Ground None 4 CN_H CAN Data High White In Out 5 V Positive DC Voltage ...

Page 3: ...y may be used to reduce noise Ungrounded thermocouples wiring options Preferred shield connection Alternate shield connection Ungrounded thermocouples should have one side tied to isolated common to reduce noise pickup Grounded thermocouples may use type 3 or 4 shield connections if shield is not grounded at field end Type 1 Type 2 Type 3 Type 4 7VAC 7VAC ...

Page 4: ...hannel 8 0 J 210 C to 1200 C 1 K 200 to 1372 C 2 N 200 C to 1300 C 3 T 200 C to 400 C 4 E 200 C to 1000 C 5 R 50 C to 1768 C 6 S 50 C to 1768 C 7 B 250 C to 1820 C 8 C 0 C to 2320 C 12 25mV 13 50mV 14 100mV 15 200mV Produced Analog Data This data is sent from the SmartBlock to the controller Normally this data is mapped into specific registers in the I O configuration in Cscape For advanced applic...

Page 5: ...ear the PLC This does not affect open thermocouple detection or measurement accuracy and reduces the effect of common mode noise if present This PLC side ground connection must not be used with grounded thermocouples or accuracy will be affected Any thermocouple should be grounded in one place at most When found on the product the following symbols specify All applicable codes and standards need t...

Page 6: ...quipment including safety glasses and insulated gloves when making connections to power circuits Ensure hands shoes and floor are dry before making any connection to a power line Make sure the unit is turned OFF before making connection to terminals Make sure all circuits are de energized before making connections Before each use inspect all cables for breaks or cracks in the insulation Replace im...