Adhere to the following safety precautions whenever any type of connection is made to the module.  

 

Connect the green safety (earth) ground first before making any other connections.  

 

When connecting to electric circuits or pulse-initiating equipment, open their related breakers.  
Do not make connections to live power lines.    

 

Make connections to the module first; then connect to the circuit to be monitored.   

 

Route power wires in a safe manner in accordance with good practice and local codes. 

 

Wear  proper  personal  protective  equipment  including  safety  glasses  and  insulated  gloves 
when making connections to power circuits.  

 

Ensure hands, shoes, and floor are dry before making any connection to a power line.  

 

Make  sure  the  unit  is  turned  OFF  before  making  connection  to  terminals.    Make  sure  all 
circuits are de-energized before making connections.  

 

Before  each  use,  inspect  all  cables  for  breaks  or  cracks  in  the  insulation.    Replace 
immediately if defective.  

 

TECHNICAL SUPPORT 

 

North America: 

Tel:  317 916-4274 
Fax: 317 639-4279 
Web:    

http://www.heapg.com

  

Email:  

[email protected]

 

Europe: 

Tel:  +353-21-4321266 
Fax: +353-21-4321826 
Web:    

http://www.horner-apg.com

 

Email:  

[email protected]

 

 

 

Cscape, SmartStix and CsCAN are trademarks of Horner APG. This information is subject to change without notice. 

Summary of Contents for SmartBlock HE579MIX577

Page 1: ... filter 1 128 scan digital running average filter ANALOG OUT Number of Outputs 2 577 or 4 977 Isolation Power to Analog Output 3K VDC 2 5K VAC Test IEC61010 1 400V RMS Output Ranges 0 5V 0 10V DC 4 20mA 0 20mA DC Isolation Method Magnetic Resolution 14 bits Output Clamp 24V 5V 600Wpk Accuracy 25 C 0 1 Output Type Sourcing Load Resistance V 500 ohms Min mA 500 ohms Max Register Value for Nominal Fu...

Page 2: ...on into a grounded back plate Alternately a ground can be connected to the spade lug Please see Horner manual MAN0799 for details on CAN wiring CAN Network Power Port Pin Assignments Pin Signal Signal Description Direction 1 V CAN and Device Ground Black 2 CN_L CAN Data Low Blue In Out 3 SHLD Shield Ground None 4 CN_H CAN Data High White In Out 5 V Positive DC Voltage Input 10 30VDC Red 2 16 54 8m...

Page 3: ...Mix577 977 Module 3 WIRING V1 I1 C V2 I2 C V3 I3 C V4 I4 C O1 C O2 C V5 I5 C V6 I6 C V7 I7 C V8 I8 C O3 C O4 C 977 Only Ox C Load Channel wiring detail with shielded cable INPUTS V V1 C I1 No Connection 10V V1 C I1 20mA ...

Page 4: ... the device to be configured Below is the configuration for MIX577 977 device Network ID This should match the ID of the rotary switch on the SmartBlock unit and should be unique to the network I O Mapping These registers define how the OCS controller registers are mapped to the data to and from the SmartBlock I O These registers do no have to match the I O types typically used for I O such as AI ...

Page 5: ...ar the PLC This does not affect open thermocouple detection or measurement accuracy and reduces the effect of common mode noise if present This PLC side ground connection must not be used with grounded thermocouples or accuracy will be affected Any thermocouple should be grounded in one place at most When found on the product the following symbols specify All applicable codes and standards need to...

Page 6: ...uipment including safety glasses and insulated gloves when making connections to power circuits Ensure hands shoes and floor are dry before making any connection to a power line Make sure the unit is turned OFF before making connection to terminals Make sure all circuits are de energized before making connections Before each use inspect all cables for breaks or cracks in the insulation Replace imm...

Reviews: