HORNER SmartBlock HE579DIQ880 Specification & Installation Manual Download Page 2

MAN0980-01-EN

          

Specifications/Installation 

10/29/2013                                   

No part of this publication may be reproduced without the prior agreement and written permission of Horner APG, LLC. Information in this document is subject to change without notice.

  

Page 

2

 of 

5

 

3.  INTERNAL WIRING 

 

Figure 1 - HE57DIQ880 Outputs 

 

 

Figure 2 - He579DIQ881 Outputs 

 

 

 

Figure 3 - HE57DIQ880/881 Inputs 

Positive Logic 

Negative Logic 

Summary of Contents for SmartBlock HE579DIQ880

Page 1: ...rt circuit Overtemp Automatic Reset Operating Temperature 0 to 60 C Max Switching Rate Limited by message rate Weight 12 oz 340 g 24VDC Supply Voltage NOTES A I O common pins C are internally connected to the power supply negative B Digital inputs are configurable for positive or negative logic using Cscape C When configured for positive logic the inputs are pulled down to common by a 10K resistor...

Page 2: ...eproduced without the prior agreement and written permission of Horner APG LLC Information in this document is subject to change without notice Page 2 of 5 3 INTERNAL WIRING Figure 1 HE57DIQ880 Outputs Figure 2 He579DIQ881 Outputs Figure 3 HE57DIQ880 881 Inputs Positive Logic Negative Logic ...

Page 3: ...the I O types typically used for I O such as AI Q Any standard controller registers may be used such as R T and M Input Update Method Defines how often analog data is sent from the SmartBlock to the CsCAN network Digital data is transmitted on change of state by default Timeout Sets the time a controller will wait before assuming the host OCS is off line Status The host controller reports a 16 bit...

Page 4: ...hold 0 105 120 Reserved Produced Digital Data This data is sent from the SmartBlock to the controller Normally this data is mapped into specific registers in the I O configuration in Cscape For advanced applications NetGet functions can be used to obtain this data Since this data is broadcasted to all controllers on the network additional controllers can use NetGet functions to obtain this data as...

Page 5: ...NING In the event of repeated failure do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse WARNING Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applic...

Reviews: