COMPRESSOR APPLICATION GUIDE:

ABOUT COMPRESSOR DUTY CYCLE:

Duty cycle refers to the amount of time a compressor can 

be operated in a given time period at 100 PSI, and a standard ambient 

temperature of 72° F. It is commonly expressed in percentage format: 

Compressor on time ÷ (on time + off time) = Duty Cycle %.

ONE-HOUR DUTY CYCLE 

9% 
10% 

15% 

20% 

25% 

30% 

33% 

50% 

100% 

MINUTES ON / MINUTES OFF

5 Min. On / 55 Min. Off 

6 Min. On / 54 Min. Off 

9 Min. On / 51 Min. Off 

12 Min. On / 48 Min. Off 

15 Min. On / 45 Min. Off 

18 Min. On / 42 Min. Off 

20 Min. On / 40 Min. Off 

30 Min. On / 30 Min. Off 

1 Hour Run Time

NOTE:

 

All compressors, regardless of rated duty cycle, require 

sufficient rest time in between cycles to allow for partial or 

complete heat dissipation. Heat dissipation rates may vary 

depending on ambient temperatures and operating conditions.

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always 

operate compressor within rated working pressure of the 

compressor.  Never use a pressure switch with a higher 

cut-off pressure than compressor’s rated working pressure. 

SPECIFICATIONS:

12 Volts 

18

 Amps 

30 Amps

Perm. Magnetic

1/4

1

2

0 PSI

30%

1

5

 On / 4

5

 Off 

40 Minutes

158°F

2

75

C AIR COMPRESSOR

Motor Voltage: 

Max. Current Consumption: 

Recommended Fuse:

Motor Type: 

Horse Power: 

Max. Working Pressure: 

Max. Duty Cycle (@72°F & 100 PSI): 

Minutes On/Off (@72ºF & 100 PSI):  

Continuous Use  (@72ºF & 40 PSI):    

Max. Ambient Temperature: 

Min. Ambient Temperature: 

Auto. Reset Thermal Protection: 

-40°F 

Yes

Summary of Contents for MC-127H

Page 1: ...Air Tank PART NO MC 127H WARNING To ensure the longevity of your system reading and following these instructions are recommended before installation Make sure to drain the moisture from your tank on...

Page 2: ...h any part of this compressor with bare hands Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being admi...

Page 3: ...rce kit will help ensure a long and trouble free service life Please pay close attention to the following guidelines 1 Select a FLAT UPRIGHT AND SECURE location where the air source kit can be mounted...

Page 4: ...round Black wire to a clean ground preferably a negative post of battery and secure with proper hardware 6 Connect positive Red lead wire from pre installed pressure switch to a fuse holder 25 amp min...

Page 5: ...cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor au...

Page 6: ...pproximately 5 PSI to 20 PSI b Drain water from tank by opening the drain cock drain valve c If drain cock is plugged release all air pressure from tank remove drain valve and clean then reinstall d A...

Page 7: ...ated duty cycle require sufficient rest time in between cycles to allow for partial or complete heat dissipation Heat dissipation rates may vary depending on ambient temperatures and operating conditi...

Page 8: ...fuse amperage 3 Let compressors cool off for about 30 Minutes to allow thermal overload switch reset 4 Replace pressure switch Thermal overload protector cuts out repeatedly 1 Lack of proper ventilat...

Page 9: ...flow lower than normal 1 Excessive air usage 2 Loose connections 3 Worn piston ring or inlet valve 4 Clogged air filter element 1 Decrease air usage 2 Check all connections wit soap and water solution...

Page 10: ...FAST FILL 120 PSI AIR SOURCE KIT WARNING This product may contain a chemical known to the State of California to cause cancer birth defects or other reproductive harm HORNBLASTERS HORNBLASTERS...