Disconnect electrical components and drain you air system before performing maintenance.

GENERAL AIR HORN SYSTEM MAINTENANCE

• Check your air horns for debris when appropriate and at least once a month and clean when necessary.

• Drain your air system at least every other week, to remove any condensation buildup on the inside of you air tank.

• Make sure you air compressor is clean and free from debris at all times.

• Periodically change your two stage air filter on your compressor.

TIPS

•  Make sure your engine is running when you air compressors are in use to insure proper voltage and to prevent damage to your

system.

•  Do not run your compressor above its maximum rated working pressure. Doing so will not only void you warranty, but may also

damage your compressor.

•  The air horns are pre-tuned to a locomotive chord and to their loudest possible tone. Do not adjust the tuning screw on the

horns. Doing so will void your warranty and may damage the horns if improperly adjusted.

CAN’T FIGURE IT OUT?

No problem! Give us a call at 813-783-8058, or email at [email protected] and we’ll be more than happy to help you fix 

you system. Also feel free to visit our online horn community, www.trainhornforums.com, for more information.

PROBLEM

MAINTENANCE & TIPS

TROUBLESHOOTING

Air horn will not sound.

1. No pressure in air tank.

2. No power or toggle switch in ‘Off’ position.

3. Blown fuse.

4.  Loose connections or bad ground in air valve circuit (circuit 1).

1. Check that air tank is pressurized.

2. Make sure all toggle switches are on.

3. Disconnect electrical components and replace fuse.

4.  Check that all electrical circuits are secure and not corroded.

Horn tone changes 

when sounded

1.  A side fitting as used to connect the air source (line from valve) to 

the 4-point banjo manifold.

2. Air line connecting the horns is not of equal length.

1.  Check that air source (line coming from valve) is entering the 

center fitting of the 4-point banjo manifold.

2.  Check that the air line connecting each horn to the 4-point banjo 

manifold is of equal length.

Excessive moisture 

in horn or safety 

discharge.

1. Excessive water in tank.

2. Compressor is exposed to high humidity.

1.  Depressurize tank using safety, then drain tank. Tilt the tank to 

drain moisture and drain more frequently.

2. Move the compressor to an area with less humidity.

Compressor will not 

run.

1. No power or toggle switch in ‘Off’ position.

2. Blown fuse.

3. Motor overheat.

4. Faulty pressure switch.

1. Make sure all toggle switches are on.

2. Disconnect compressor from power & replace fuse (35A).

3.  Let compressor cool off for about 30 minutes for thermal 

overload switch to reset.

4. Replace pressure switch.

Thermal overload 

protector cuts out 

repeatedly.

1. Lack of proper ventilation/ambient temperature too high.

2. Compressor valves failed.

1.  Move compressor to a well ventilated area or an area with a lower 

ambient temperature.

2. Replace air compressor.

Excessive knocking or 

rattling

1. Loose mounting bolts.

2. Worn bearing on eccentric or motor shaft.

3. Cylinder or piston ring is worn.

1. Tighten bolts.

2. Replace compressor.

3. Replace compressor.

Tank pressure drops 

when compressor 

shuts off

1. Loose drain cock.

2. Air valve or check valve is leaking.

3. Loose connections.

4. Defective safety valve.

1. Tighten drain cock.

2. Replace air valve or check valve.

3.  Check all air connections with soap and water solution and 

tighten as necessary.

4. Replace safety valve.

Compressor runs 

continuously and air 

flow lower than normal

1. Excessive air usage.

2. Loose connections.

3. Worn piston ring or inlet valve.

4. Clogged air filter element.

1. Decrease air usage.

2.  Check all connections with soap and water solution and tighten 

as necessary.

3. Replace compressor

4. Replace air filter element.

Compressor runs 

continuously causing 

safety valve to open.

1. Faulty pressure switch.

2. Defective safety valve.

1. Replace pressure switch.

2. Replace safety valve.

Summary of Contents for 127VX

Page 1: ...TION MANUAL 127VX 228VX 238VX 248VX WARNING To ensure the longevity of your system reading and following these instructions are recommended Make sure to change filters and to drain the moisture from y...

Page 2: ...ncluded components with 12 volt DC systems only Do not leave the air system unattended during use WARNING To prevent injury Never allow children to operate the compressor or air horn Use close supervi...

Page 3: ...The horns should not be mounted where they will be completely submerged or will receive any kind of impact Horns may be mounted directly to your vehicle on a medium such as grommet strips plumber s st...

Page 4: ...ctory Horn Wire Toggle Switch Air Valve Ground AIR SOURCE WIRING FLOW CHART Remote Wire Accessory Wire Inline Fuse Air Source Unit Ground CIRCUIT 1 1 Begin by wiring your horn trigger a If you are int...

Page 5: ...line connecting the horns is not of equal length 1 Check that air source line coming from valve is entering the center fitting of the 4 point banjo manifold 2 Check that the air line connecting each...

Page 6: ...edia Please provide us with the highest quality media to prevent video degradation We can read all formats of video We recommend using either the default your camera records with or if you are compres...

Page 7: ...ded Make sure to change filters and to drain the moisture from your tank on a regular basis Most factory horns are positively activated If your horn system is negatively activated then you will need t...

Page 8: ...6511 N 54th St Tampa FL 33610 1 813 783 8058 Fax 1 813 783 2407 www hornblasters com support hornblasters com...

Reviews: