4
einseitig / uni-directional
zweiseitig / bi-directional
Betriebsspannung
Operating voltage
6 V -
6 V -
Ladespannung
Charging voltage
12 - 30 V
12 - 30 V
Energie
Energy
0,4 Ws
0,8 Ws
Blitzfolge
Flash frequency
ca. 60/min.
ca. 60/ min
Betriebsstunden
Operation
> 100h
> 50h
Stromaufnahme
Current consumption
70 mA
140 mA
Maße
Dimensions
190 x 160 x 390 mm
190 x 160 x 390 mm
Gewicht (ohne Akku)
Weight (without battery)
ca. 1100g
ca. 1100g
Versorgung
Power supply
dryfit-Akku 6V/ 7Ah
dryfit-Akku 6V/ 7Ah
Technische Daten · Technical data
Technische Änderungen vorbehalten ! Subject to alterations !
en
Charging of the built-in battery
Open the lamp, take out charge adapter and close lamp again.
Caution:
make sure to open the lamp carefully as the upper part and the rechargeable battery are cable-connected.
Connect the charging adapter with the socket at lamp‘s back and 230V mains. Proper charge function is indicated
by a red indicator LED at lamp‘s upper part. As soon as the battery is fully charged the LED will light up green.
In case the battery is nearly discharged due to extended operation times, the initial charging process will be exe-
cuted with lower power. During the period of charging with lower power, the red LED will not light up until normal
charging process is achieved. Charging is unlimited (overcharging protection). After charging return charge adapter
into the lamp.
CAUTION:
Before first use, the rechargeable battery has to be connected to the electronics and charged for at least 14 hours!
In order to do so, open the housing and connect the two wires according to the corresponding colour with the
rechargeable battery.
Left idle for a period longer than 2 months, or if being restored, the battery has to be disconnected from the
electronic.
Euro-Blitz is equipped with a deep-discharge protection, switching the lamp off automatically in case of discharged
battery. Please take notice of the maximum operation hours which can be reached with one charge.
NOTE:
Rechargeable batteries are subject to a technologically caused self-discharge process (chemical process). Due to
this process, also fully charged batteries will discharge slowly even when not being used and may get permanently
damaged.
Therefore please keep to the following instructions:
- left idle, batteries
need to be recharged regularly
after a period of approx.
2 months,
- in case the device was deactivated due to deep discharge protection,
switch off
the device
with the ON/OFF switch,
- in case the device was switched off due to deep discharge protection, the battery has to be
recharged com-
pletely