Operating instructions for GPS SECURITY and SMS CONTROL: 

Installation and connection:
The additional device GPS SECURITY and SMS CONTROL device are built in operable in the electric fencer. Please 
let your SIM card unlock with the help of the enclosed documents.

Operation of the additional device GPS SECURITY and SMS CONTROL:
Please connect the electric fencer with the 12 V battery The additional module is available after 2 minutes approxi-
mately.
Status check by calling the additional device and status advise for status information via SMS:
Please call to the additional device from a cell phone. The call will be interrupted after 2 call signs.
You will get an SMS from the additional device with following information, which you will get with each status update:
 
http://maps.google.com/maps?f=q&hl=en&q=……  
You can enter the coordinates by yourself in google-maps and query the location. The link can be opened immediately 
from your mobile phone (Smartphone) in google-maps. The location of the electric fencer will be shown. 

loc: 51.286368,8.857165

 ..........Location coordinates of the electric fencer

&speed: 0.00

 ............................Current speed of additional device over ground

01/01/13 11:55

 .........................Date and time of the last allocated location

F:4,32V

 ....................................current voltage of backup battery of the additional 

module

M:12,0V

 ...................................Current voltage of the 12 V main power source*

Signal: F oder L

 .........................F means that the GPS signal suffice for the esta-

blishment. L means that the GPS signal is insuffici-
ent for the establishment.

Imei:012896000578432

 ............Device identification number

* Voltages above 12 volts are shown as 12V (and not 

as 13,6 volts for example). The voltage value can 

fluctuate at +/- 0,4 volts around the shown value.

Alert message:
You will get following alert messages from the device if the voltage limits are rea-
ched or the location of the electric fencer has changed:

Signal:F low voltage

 .................The voltage of the 12 V main power source has fallen to 11,4 Volt or less

Signal:F Low batt

 ......................The voltage of the internal backup battery ensures operation of the additional device 

for a few more minutes. During this time, the additional device can’t communicate with 
you, until the electric fencer is again  connected to the power source.

Signal:F moved

 .........................The electric fencer has been disconnected from it`s referred location.

Location and 

movement functions:

Send a SMS to the additional device with following content:           

 

move

 

The given answer of the additional device will be:  

 

move ok

The additional device will memorize the location. If the fencer is moved more than 300 m from the allocated location, 
the mobile phone which was sending “move”, will get a SMS again.
Content of the SMS will be:  

 

Signal:F moved

Send a SMS to the additional device with following content:               

 

nomove 

The given answer of the additional device will be:                             

 

nomove ok

The additional device will not memorize the location. Relocation will not be reported in the future.

Advise: Before you register your fencer in a new location you have to cancel the previous location  with nomove.

http://maps.google.com/

mapsßf=q&hl=en&q=loc

:51.286368,8.857165&sp

eed: 0.00 01/01/13 11:55 

F:4,32V Signal:F Imei: 

012896000578432

additional device:

en

Operating instruction for electric fence controller ranger A70
with GPS SECURITY and SMS CONTROL (D)

 

    in connection with safety hints SECURA ANIMAL or SECURA SECURITY  (www.horizont.com)

Installation and connection:  The controller can be mounted alternatively onto a wall or a solid post.
The earth stake must be inserted into the ground as far as possible at a moisty place and must be connected to the 
earth terminal ( 

 ) of the controller by means of a noncorrosive wire. 

Connect the fence connecting lead to the fence terminal (   or   ) - fig. 3
The controller is water protected only when being installed acc. the instructions. Prodect from bright sunshine. Do not 
operate the energizer when laying on the ground.

Operation (see page 3 / fig. 2): Connect the controller to a 12V wet battery ( red + / black - ), ensure that the terminals 
are absolutely clean and the polarity is correct.  Use only rechargeable 12V- lead-acid batteries, during charging lead-
acid batteries must be placed in a well-ventilated area.
Integrated horizont load sensing circuitry: less strain on the environment. The load sensor automatically adjusts 
the output to give the appropriate power to the fence line depending on vegetation or leakage. This horizont paten-
ted system ensures that the fencer only draws as much current from the battery as strictly necessary to provide the 
correct output power for the fence conditions. This ensures both the security on the fence and that the battery life is 
extended as long as possible thereby reducing operating costs (check battery anf fence regularly). 

Especially suita-

ble for solar operation!
Press the switch 

(1)

The battery indicator light 

(2)  „accu-test“  is   permanent green          = battery is fully charged

                          no light or flashing green = battery must be charged
After a few seconds a slight tic-tac can be heard. The fence voltage level 

(3) flashes with the pulses. In case of wrong 

polarity  the controller will not operate. 
The 6 controllamps 

(3) indicate the fence voltage in 1000V steps. At least 3 lamps should flash (3000V) to ensure 

sufficient voltage and fencing.  Possible reasons, when the voltage is too low:
a) with fence:  

heavy vegetation on the fence, insulator flash-over or fence too long. 

b) without fence:  

the energizer is faulty, see service.

page 3 / fig. 2: The energizer has two fence terminals  (Z1)    = max output 

 (Z2) = reduced output

Both outlets can operate separate fences at the same time. A short in the  Z2 fence has no strong influence on Z1 but 
a short or a deviation in Z1 means a further reduction of Z2.
By operating with two fence systems ( Z1 + Z2 ) the indication lamps show the reduced output only.
ranger A70: 

Also after the delay time of 60 seconds the Electric Fence Ener-

gizer will not release more than 5 Joules!

Testing grounding (4): Produce with a metal stake against the fence wire (no plastic) a short 
circuit (ca. 50m distance to fencer). Max. 1 lamp (wet ground) or 2 lamps (dry ground) may 
shine. Otherwise drive in more stakes (see picture).

Service:  Servicing is only to be made by qualified service personell. 
Only by the manufacturer commanded replacement parts must be used.

Fig. 3

Fig. 4

Installation and connection 

Summary of Contents for 10852GPSD

Page 1: ...0 56 31 5 65 1 00 Telefax 49 0 56 31 5 65 1 20 agrar horizont com www horizont com BETRIEBSANLEITUNG Elektrozaunger t de OPERATING INSTRUCTION Electric Fencer en MODE D EMPLOI lectrificateur de Cl tu...

Page 2: ...60188 60219 90764 97690 84719 88148 94581 97683 60688 97929 84741 89474 94581 90005 1 89976 Z2 Z1 90739 2 4 98271 schwarz 97999 rot 97999 rot 90838 Fig 1 Ersatzteile Spare parts Pi ces d tach es Fig...

Page 3: ...l 2 Lampen trockener Boden zum Aufleuchten bringen im anderen Fall siehe Bild ist die Anzahl der Erdpf hle zu erh hen Service Reparaturen d rfen nur von qualifizierten Personen durchgef hrt werden Es...

Page 4: ...on sowie mit bis zu vier weiteren Mobiltelefonen Hierzu m ssen sie ihr Mobiltelefon zun chst als Master anmelden Schicken Sie eine SMS an das Zusatzmodul mit folgenden Inhalt admin IHRE Mobiltelefonnu...

Page 5: ...f q hl en q loc 51 286368 8 857165 sp eed 0 00 01 01 13 11 55 F 4 32V Signal F Imei 012896000578432 additional device en Operating instruction for electric fence controller ranger A70 with GPS SECURI...

Page 6: ...e des pi ces de rechange ordonn es par le producteur Fig 3 Fig 4 Montage et raccordement Switch on and off of the electric fencer Send a SMS to the additional device with following content poweron The...

Page 7: ...aux satellites GPS pour viter les temps de retard lors de la localisation du site ou impr cision lors de la connexion Mode d emploi pour GPS et GSM Contr le de s curit Installation et raccordement Le...

Page 8: ...D 12 V DC 150 880 mA 6 6 Joule Technische nderungen vorbehalten SUBJECT TO technical ALTERATIONS SOUS R SERVE DE CHANGEMENTS TECHNIQUES CEE max Zaunl nge 130 km 3 ranger A70 ranger A70 130 km ranger A...

Page 9: ...16...

Reviews: