51
7.0 TROUBLESHOOTING
LCD,LEDandBeepofthestatusduringprocedures
#
Procedure
LCD
LED
Beep
Status
System
Reaction
1 Starting
up
Horizon
/Fuel Cell
Green
flashing
Long
beep
Normal Starting
up
2 Starting
up
System
off/Battery
Low
Red
flashing
Long
beep
Battery
voltage is too
low
Shut down
3 Starting
up
System
off/FC
Voltage
Low
Red
flashing
Long
beep
Stack voltage
is too low
Shut down
4 Starting
up
System
off/H2%
High
Red
flashing
Long
beep
Hydrogen
leaks
Shut down
5 Running
E: B:
T: U:
I:
Green
light on
NONE
Normal Running
6 Running
System
off/FC
Voltage
Low
Red
flashing
Long
beep
Stack voltage
is too low
Shut down
7 Running
System
off/H2%
High
Red
flashing
Long
beep
Hydrogen
leaks
Shut down
8 Running
System
off/Current
High
Red
flashing
Long
beep
Stack current
is too high
Shut down
9 Running
System
off/T High
Red
flashing
Long
beep
Stack
temperature
is too high
Internal load will
switch off until
stack
temperature is
satisfied
Summary of Contents for H-500XP
Page 1: ...1 Date 2013 12 16 Item Number H 500XP Version 20131216 Manual H 500XP Fuel Cell System User ...
Page 6: ...6 1 0 SAFETY ...
Page 12: ...12 2 0 PART LIST ...
Page 18: ...18 3 0 GENERAL INFORMATION ...
Page 27: ...27 4 0 SYSTEM SET UP ...
Page 42: ... 42 5 0 SOFTWARE ...
Page 47: ... 47 6 0 MAINTENANCE ...
Page 50: ... 50 7 0 TROUBLESHOOTING ...