VERT Series Owner’s Manual 

 

7

 

 

 

 

  

 

Specifications: 

MODEL 

VERT  

HEIGHT 

33.5” 

WIDTH 

20.5” 

LENGTH 

16.5” 

WEIGHT 

110.00 LBS 

AIRFLOW 

360 CFM 

MOISTURE REMOVAL  
AT 80F/60% RH 

100 PINTS PER DAY 

POWER SUPPLY 

115 VOLT/60 HERTZ SINGLE 

PHASE 

FINISH 

POWDER-COATED EPOXY 

OPERATING RANGE 

45 F TO 90 F 

REFRIGERANT 

See Data Label 

CONDENSATE DRAIN SIZE 

8 mm Quick Connect 

AMPS (FULL LOAD) 
AT 80F/60% 

7.5 FLA 

POWER CORD 

20’ GROUNDED PLUG 

FILTER SIZE 

20x14” 

 

 

Parts List 

 

DH-100-101 

 

Compressor 

DH-100-101 

 

Humidistat 

DH-100-102 

 

Blower w/ Capacitor 

DH-100-103 

 

Thermostat 

DH-100-104 

 

Compressor Capacitor 

DH-106  

 

Power Cord 

DH-100-107 

 

Control Board 

DH-100-108 

 

Condensor Coil 

DH-100-109 

 

Evaporator Coil 

 

 

 

Summary of Contents for VERT series

Page 1: ... or ri iz zo on n V VE ER RT T I In ns st ta al ll la at ti io on n a an nd d O Op pe er ra at ti io on ns s M Ma an nu ua al l R Re ea ad d a an nd d S Sa av ve e T Th he es se e I In ns st tr ru uc ct ti io on ns s Distributed Exclusively By Air Cleaning Equipment Inc Broadway NC 27332 www horizondehumidifiers com ...

Page 2: ...__________________________________________ VERT Series Owner s Manual 2 Horizon VERT Humidistat Fan Switch O Auto I Constant On Drain Line Connection Push line into to secure Release by pushing in blue ring surrounding tube and pull tube out ...

Page 3: ...t unit the unit should be opened and allowed to dry thoroughly before reconnected to electric and restarting For proper operation neither the inlet nor discharge should be positioned against a wall The inlet requires a minimum of 12 clearance and the discharge needs a minimum of 24 clearance For proper diffusion of air throughout the room the dehumidifier should be positioned so that the discharge...

Page 4: ...3 Do not use extension cord 4 Do not use plug adapter Power Supply 115V 60 Hz AC Only 1 Phase Outlet Requirement 3 Prong GFI Circuit Protector 15 Amp Time Delay Fuse or Circuit Breaker Principle of Operation The VERT Series Dehumidifier utilizes its integral humidistat or optional remote mount humidistat to monitor the conditioned space When the relative humidity goes above the selected set point ...

Page 5: ...ntation wait a minimum of 2 hours before turning the unit on Drain Line o Standard Unit Unit has a quick connect adapter on its side for connection of the included 8 mm drain line 25 of drain line is included Route drain line to drain or outside of the area Drain line MUST have a downward slope to drain or condensate pump Plug unit into 15 amp grounded outlet Determine whether you want constant fa...

Page 6: ...til cleaning interval for your application can be properly established In most instances the filter can be vacuumed once after approximately 3 months and then replaced after approximately 6 months Maintenance Proper maintenance of air filters is required to prevent extensive cleaning of heat exchanger and coils 1 Unplug Unit 2 Filter may be cleaned by a Vacuuming b Or Replace with similar 20 x 14 ...

Page 7: ... 115 VOLT 60 HERTZ SINGLE PHASE FINISH POWDER COATED EPOXY OPERATING RANGE 45 F TO 90 F REFRIGERANT See Data Label CONDENSATE DRAIN SIZE 8 mm Quick Connect AMPS FULL LOAD AT 80F 60 7 5 FLA POWER CORD 20 GROUNDED PLUG FILTER SIZE 20x14 Parts List DH 100 101 Compressor DH 100 101 Humidistat DH 100 102 Blower w Capacitor DH 100 103 Thermostat DH 100 104 Compressor Capacitor DH 106 Power Cord DH 100 1...

Page 8: ...s not include any cost of labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will be sent to customer at customer s expense ACE shall not be responsible for loss of use of any product loss of time inconvenience or damage to other equipment or any other in...

Reviews: