Horizon Fitness MobileMesh Manual Download Page 3

 

a.

 

Screw on two TNC-type antennas, ensuring they are the correct frequency for your MobileMesh 
radio. We do not recommend powering the MobileMesh without antennas attached. 

3.

 

Power on the MobileMesh Radio: 

a.

 

Momentarily depress the power switch on the side of the MobileMesh. The Battery and Status 
LEDS should come on to let you know power is on. 

 

4.

 

Connect to your host PC: 

a.

 

Using H31-MM-CAB-RJ45 (Primary to RJ45) or H31-MM-CAB-USBA-MALE (Primary to USB-A), 

connect the MobileMesh radio to your host PC. If you use H31-MM-CAB-USBA-MALE, your 

system will enumerate a new Ethernet interface which you will set up in the step below.  If you 

use the RJ45 cable you will set up an existing Ethernet interface. 

i.

 

The Primary connector has 14 pins and is labeled 

PRI

 

ii.

 

To insert the connector, align the red dot and press down 

iii.

 

To remove the connector, pull upward from the base of the connector. Do not pull on 

the cable. 

5.

 

Set up your network: 

a.

 

Each radio comes from the factory with a 10.223.x.x address. This can be changed later by the 
user, but should you ever need to reset the radio, it will default back to this address. The IP 
address is provided on a label attached to each radio. 

b.

 

To connect, 

you need your host computer set up in the same subnet

Momentarily depress to turn the 
MobileMesh handheld on. To turn off, 
depress and hold for several seconds. 

Summary of Contents for MobileMesh

Page 1: ...roughput of up to 100 Mbps The MobileMesh radio is ideally suited as the ground control station radio in unmanned systems applications It can be connected to a computing device using USB A USB C or Et...

Page 2: ...Commerce any other foreign nation foreign area or foreign non government entity engaging in long term patterns or serious instances of conduct significantly adverse to the national or economic securit...

Page 3: ...nterface which you will set up in the step below If you use the RJ45 cable you will set up an existing Ethernet interface i The Primary connector has 14 pins and is labeled PRI ii To insert the connec...

Page 4: ...ere is no password set For in depth setup and configuration options related to the internal radio refer to the Doodle Labs Smart Radio J Embedded documentation https doodlelabs com technologies techni...

Page 5: ...ire storage space on the Doodle Please see Updating The Firmware section below TACTICAL LED MODE If the user desires the LEDs to be off the LED system can be put into a tactical mode In this mode both...

Page 6: ...radio via ssh or scp be sure and enable ssh access via the web UI As a reference refer to the LED control project which executes on the Doodle radio https github com horiz31 mobilemesh_led_control USI...

Page 7: ...Primary pinout Pin side Pin Number Function Direction Notes 1 USB_CC IN Only used for USB C 2 GND PWR 3 NC 4 ETH_RX IN 100 Mbps Ethernet 5 ETH_RX IN 100 Mbps Ethernet 6 ETH_TX OUT 100 Mbps Ethernet 7...

Page 8: ...NC 12 NC 13 ETH_TX OUT 100 Mbps Ethernet 14 TIMEPULSE Custom cables are available or blunt cut cables H31 MM CAB PRI BLUNT can be ordered for custom connectivity options AUXILLARY CONNECTOR The connec...

Page 9: ...the host computer connected Via the Primary ODU USD interface 3 USB D BIDIR This USB connection is a downstream port of a hub connected to the host computer connected Via the Primary ODU USD interface...

Page 10: ...scripts https horizon31 com wp content uploads mobilemesh_install zip 2 Unzip the contents 3 On Windows open a powershell window and run install bat IP ADDRESS being sure to type the actual IP addres...

Page 11: ...2 176 since 0x7A 122 and 0xB0 176 This full IP address in this case would be 10 223 122 176 6 You will need to reload Horizon31 specific scripts which control the LED and GCS connectivity as these are...

Page 12: ...e available upon request NDA Environmental Temperature 40 C to 85 C Humidity 0 95 non condensing IP67 pending formal testing Security AES 256 FIPS Level 2 Compliant NSA Suite B Available Interfaces Pr...