![background image](http://html1.mh-extra.com/html/horeca-select/ggw1001/ggw1001_instruction-manual_2162095021.webp)
3
TECHNICAL CHARACTERISTICS
GGW1001
GGW2001
Power supply
V
230V
~
Frequency Hz
50
Max. power consumed
kW
2,9
Boiler element power
kW
2,6
Tank element power
kW
1,6
Wash pump power
kW
0,3
Water supply pressure
kPa
200-400
Water supply temperature
°C
50 – 60
Version “A” water supply temperature (incorporated water softener)
°C
15 – 30
Water supply hardness
°dF
7 – 12
Water consumption per rinse
l
2,4
Wash water temperature
°C
55-60
Rinse water temperature
°C
80-85
Boiler capacity
l
2,7
Tank capacity
l
10
Standard cycle duration with water supply at 50°C
s
120
Noise level
dB(A)
56
Net Weight
kg
38
Power cable type
HAR
H07RN-F
ambient temperature max
°C
40
NOTE: “PS” = versions with integrated drain pump – “A” = versions with integrated water-softener