 RC-F

UNCTION 

B

OARD 

7406RC

 

D

ESIGN

 

 

 

 12 / 27 

7406RC Slave Clock Control Board for System 7001RC - V02.03 

hopf 

Elektronik GmbH 

Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]

 

 

4.3  

7406RC Board Assembly Overview  

DS1 - DS2 : standard ex works (Standardeinstellung ab Werk)

X2

J1

J14

MB3

J5

J2

J4

J6

60V
48V
24V

J11
J12
J13

60V
48V
24V

J8
J9
J10

1 2 3 4 5 6 7 8

on

DS2

1 2 3 4 5 6 7 8

on

DS1

ST3

1

1

Del

ta R

ibbon

 24

-p

o

le 

fe

m

a

le

V

G

-l

e

dge

 64

 po

le

 m

al

e

 

Description 

Function 

ST3 

Service connector 

X2 

Diagnosis connector 

J14, J6 

Service jumper 

MB3, J1 

Operating voltage measuring points (5 V DC) 

J8, J9, J10 

Voltage monitoring setting for line 1 

J11, J12, J13 

Voltage monitoring setting for line 2 

J2, J3 

Diagnosis jumper line 1 

J4, J5 

Diagnosis jumper line 2 

4.3.1   Line Voltage and Monitoring Device Configuration 

The lines of RC Function Board 7406RC can be operated with various voltages. For this 
purpose, jumpers 8-13 (see imprint) must be pre-set for voltage monitoring. 

 
 

Jumper setting 

Line 1 

Line 2 

Line voltage 

Monitoring voltage 

Line fault on insufficient voltage 

J13 

J10 

24 V 

18 V 

J12 

J9 

48 V 

36 V 

J11 

J8 

60 V 

45 V 

 

Summary of Contents for 7406RC

Page 1: ...anual Slave Clock Control Board for System 7001RC Model 7406RC ENGLISH Version 02 03 29 11 2010 _____________________________________________________________ Valid for Devices 7406RC with FIRMWARE fro...

Page 2: ...406RC Slave Clock Control Board for System 7001RC V02 03 hopf Elektronik GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail info hop...

Page 3: ...ACH OTHER THEY INDICATE THE FUNCTIONAL CORRELATION BETWEEN DEVICE AND TECHNICAL MANUAL THE DIGITS AFTER THE POINT IN THE VERSION NUMBER INDICATE CORRECTIONS IN THE FIRMWARE MANUAL THAT ARE OF NO SIGNI...

Page 4: ...erated with the voltage supply indicated on the identification label The device should only be operated by qualified staff or employees who have received specific instruction If a device must be opene...

Page 5: ...umbers available 13 5 2 Set the Board Number 13 5 3 Installation of a new Board 7406RC in the System 7001RC 14 5 4 Parametrize Activating the Board 7406RC in the System 7001RC 15 6 Administration of t...

Page 6: ...Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail info hopf com 10 Appendix 26 10 1 Connection Examples for Two Minute Lines with voltage monitoring 26 10 2 Connection Exa...

Page 7: ...et independently The pulse lengths are adjustable in pole changing operational mode A constant voltage supply source external to the system 7001RC can be connected to RC Function Board 7406RC to contr...

Page 8: ...com 2 Clocks in Pole Changing Pulse Operation In pole changing operation lines transmit every second for second lines and every minute for minute lines alternately a positive or negative voltage pulse...

Page 9: ...et http www hopf com E Mail info hopf com 3 DCF77 Time Code Clocks In DCF77 time code operation lines transmit a DCF77 time code signal changing pole on every second change The DCF77 time code signal...

Page 10: ...supply source 9 21 U additional external line voltage supply source 2 10 14 15 22 GND external line voltage supply source GND_LU 3 Relay normally open contact 4 Relay normally closed contact 16 Relay...

Page 11: ...ermanently off Line is ready for operation 4 2 VG Ledge 64 pin DIN 41612 c a 32 1 20 10 Connector DIN41612 64 pin VG male Connector DIN 41612 64 pin VG male Pin c a Pin 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8...

Page 12: ...emale VG ledge 64 pole male Description Function ST3 Service connector X2 Diagnosis connector J14 J6 Service jumper MB3 J1 Operating voltage measuring points 5 V DC J8 J9 J10 Voltage monitoring settin...

Page 13: ...via the SHOW ALL ADDED SYSTEM BOARDS menu The board numbers that are not listed for this board type are available for the new board Boards that are available in terms of hardware but which have not y...

Page 14: ...off on on off off 12 off on on off on 13 off on on on off 14 off on on on on 15 on off off off off 16 on off off off on 17 on off off on off 18 on off off on on 19 on off on off off 20 on off on off...

Page 15: ...our of the board it is first parameterized and then activated by switching it into the monitoring system In the BOARD SETUP menu sub heading ADD SYSTEM BOARDS log on the newly installed board In the B...

Page 16: ...RDS PARAMETER menu be confirmed by pressing the ENT key 6 1 Input Functions for the Board 7406RC in the System 7001RC The input and display functions of the board parameters are polled in the menu hea...

Page 17: ...e numbered in descending order Bit 7 Hour Mode Slave Line 1 0 12 hour operation 1 24 hour operation Bit 6 Slave Lines SL 2 as minute or second lines 0 Minutes SL1 Seconds SL2 1 Minutes SL1 Minutes SL2...

Page 18: ...line numbers in the system Bit 6 0 1 minute line and 1 second line The 2nd line of the Board is used to control the seconds line With this setting Board 7406RC occupies only one common line number in...

Page 19: ...Bit 7 Radio status fault signal 0 In common signal 1 No radio status fault signal Bit 6 Pole changing pulse operation DCF77 time code 0 DCF77 time code line 1 Clocks with pole changing pulse operation...

Page 20: ...DCF77 time code mode The line output time for clocks is set up with the following function Bit 5 1 Local time output with any ST WT changeover points Bit 5 0 UTC time output without ST WT changeover p...

Page 21: ...4 0 6 N O 0 1 L I N I E 0 1 P U L S E 0 2 S E C N E W P U L S E S E C The selected line number 01 or 02 and the associated currently set pulse time are displayed on the top line The pulse time is re...

Page 22: ...time 00 00 00 23 59 59 confirm with the ENT key To set the slave lines to the current time e g on first installation or after maintenance work the slave line time must be re entered Care should be ta...

Page 23: ...reception status FUNK RADIO system synchronisation is faulty 7 1 Line Failure Line Voltage Power Failure A short circuit or line break in parts of the installation can interrupt the pulse output By f...

Page 24: ...ime Code Clocks are still running and other clocks which are further away are not running anymore After the fault has been removed the output of the DCF77 time telegram continues and voltage is suppli...

Page 25: ...ssary 9 Technical Data General Data Board dimensions Eurocard 160 x 100 mm 4HP 3U Number of slave lines max 2 MTBF 150 000 hours Power Supply Internal system voltage VCC 5V DC 5 via system bus Line vo...

Page 26: ...GmbH Nottebohmstr 41 D 58511 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail info hopf com 10 Appendix 10 1 Connection Examples for Two Minute Lines with volt...

Page 27: ...11 L denscheid Tel 49 0 2351 9386 86 Fax 49 0 2351 9386 93 Internet http www hopf com E Mail info hopf com 10 3 Connection Example for DCF77 Time Code Clocks with voltage monitoring If pulse monitorin...

Reviews: