COM0
/
COM1
S
ERIAL
I
NTERFACES
114 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
6.3.12.2 Structure
Character No.
Meaning
Hex-Value
1
"$" string start
$24
2
"G" identifier time basis GPS
$47
3
"P"
$50
4
"Z" identifier time information data
$52
5
"D"
$4D
6
"A"
$43
7
"," comma as separation
$2C
8
tens hour (UTC)
$30-32
9
unit hour (UTC)
$30-39
10
tens minute (UTC)
$30-35
11
unit minute (UTC)
$30-39
12
tens second (UTC)
$30-35
13
unit second (UTC)
$30-39
14
"." comma as separation
$2C
15
tens day (UTC)
$30-33
16
unit day (UTC)
$30-39
17
"." comma as separation
$2C
18
tens month (UTC)
$30-31
19
unit month (UTC)
$30-39
20
"." comma as separation
$2C
21
thousands digit year (UTC)
$31-32
22
hundreds digit year (UTC)
$30, $39
23
tens year (UTC)
$30-39
24
unit year (UTC)
$30-39
25
"," comma as separation
$2C
26
"+" or "-" sign local time zone
$2B, $2D
27
tens hour (local time zone diff.)
$30-32
28
unit hour (local time zone diff.)
$30-39
29
"," comma as separation
$2C
30
tens minute (local time zone diff.)
$30-35
31
unit minute (local time zone diff.)
$30-39
32
"*" string limitation
$2A
33
tens checksum
$30-39, $41-46
34
unit checksum
$30-39, $41-46
35
CR (carriage return)
$0D
36
LF (line feed)
$0A
6.3.12.3 Status
This data string contains no status information.