4.2 Power-on system
To ensure that the electrical connection is completed, the power on operation can be performed
and the inverter will be turned on.
Step 1:
Close the AC circuit breaker between the inverter and the power grid.
Step 2:
Put the inverter's "DC SWITCH" in the "ON" state.
Carry out the above steps, if the system does not have faults, the inverter will start automatically
when the starting condition is satisfied.
4.3 System shutdown
Attentions
After the inverter is powered off, there will be residual electricity and residual heat in the case,
which may cause electrical shock or burns. Please be sure to operate the inverter after 5
minutes in the inverter system.
When the power system is running, please follow the instructions and safety rules in this
chapter.
Step 1:
Turn off the inverter by means of data collector or APP software.
Step 2:
Disconnect the circuit breaker between the inverter and the power grid.
Step 3:
Put the inverter's "DC SWITCH" in the "OFF" state.
--This chapter end--