Possible Cause

Possible Solution

• Incorrect carpet height setting

Move carpet height control to a higher
setting 

Problem: Cleaner won’t run

P ro bl e m : Cleaner/ tools won’t pick up

Possible Cause

Possible Solution

• Broken or worn belt

Replace belt

• Agitator brush roll worn

Replace brush roll

• Filter bag full

Change filter bag

• Incorrect carpet height setting

Move nozzle control knob to lower 

s e t t i n g

• Blockage in air flow passage

Clear blockage

Problem: Cleaner hard to push

4. If you have a

problem

Possible Cause

Possible Solution

• Not firmly plugged in

Plug unit in firmly

• No voltage in wall plug

Check fuse or breaker

• Blown fuse or tripped breaker

Replace fuse or reset breaker

•Thermal protector activated 

Allow cleaner to cool for 30 minutes 

(this will reset the thermal protector)

If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the checklist below.

Problem: Powered hand tool brush

roll won’t run

Possible Cause

Possible Solution

• Too much pressure being applied to

tool

Continue using tool applying 

light

pressure

• Blockage in turbine channel

Remove blockage

• Broken or worn belt

Replace belt

• Low cleaner suction

Check items under “Cleaner suction
low”

Clearing blockages

Disconnect cleaner from electrical
outlet.

Low suction or pick up may be due to a
blockage in the system.  Refer to the fol-
lowing steps to check for blockages

continuing with each step until the
blockage is found:

1. Check fullness of filter bag; change if
needed.

4 - 1

4 - 3

Checking under bottom plate

4. Turn cleaner OFF and unplug.

5. Remove bottom plate, belt and agita-
tor (see “The belt” section).

Look into opening (D) for blockages and
remove.

6. Remove agitator shield (see Fig. 3-
13) and remove any loose debris which
may have accumulated under it.

If blockage occurs during
powered hand tool use

Checking airflow path

2. Plug cleaner in and turn ON.  Check for
suction at end of hose (A).

a. If there is

suction,

continue with  

step 3.

b. If there is 

no suction

, check for

blockage in hose and dirt tube as 
follows: 

1) Disconnect hose from dirt duct (C)

by reversing  procedure for “Attach
hose” on p. 4, Figs. 1-11 and 1-12.

2) Clear out hose.

3) Look into (C) and remove blockage.

3. Check connection at hose tube (B);
remove any blockage.

1. Disconnect powered hand tool from
hose. Remove bottom plate, belt guard
and turbine as described in Figs. 3-18,
3-19 and 3-26.

Remove any blockage from turbine
channel (D).

Replace belt turbine, brush roll, belt
guard and bottom plate.

D

A

B

A

B

C

D

4 - 2

C

Hoover Cleaning
Performance

This Hoover Cleaning Performance
System is for comparing the relative pro-
gressive performance of 

Hoover

uprights only

and not for comparison

with any other brands. The majority of
this rating is based upon the American
Society for Testing and Materials (ASTM)
Carpet Cleaning Effectiveness Testing
(ASTM Test F608). Other performance
factors include Hose Power (ASTM Test
F558), Surface Litter Cleaning, Hard
Floor Cleaning, Edge Cleaning, Air
Filtration and Cleaning Width.

Summary of Contents for WindTunnel U5465-900

Page 1: ...dTunnel by HOOVER Congratulations on your purchase This WindTunnel vacuum cleaner takes HOOVER Type Y Allergen Filtration filter bags This product was designed for easy Assembly See page 3 www hoover...

Page 2: ...ays turn off this appliance before connecting or disconnecting hose Do not use without dust bag or filters in place C h a n ge bag frequently when p i cking up very fine materials such as pow d e r Us...

Page 3: ...9200 for an automated referral of authorized service outlet locations U S only OR 1 330 499 9499 to speak with a representative in our Consumer Response Center OR Visit us online at www hoover com to...

Page 4: ...into the 3 notches and the clip as shown Slide hose into B and twist hose to lock it into place Lift hose tube cover C NOTE Hose must be connected as shown for all operations D B C B E A 4 Remove bag...

Page 5: ...lectrical outlet To turn cleaner ON push switch up To turn cleaner OFF push switch down 1 2 3 4 3 3 5 6 7 8 9 10 11 12 13 13 14 14 15 16 17 18 19 20 21 22 23 24 STEP III Position tools household use P...

Page 6: ...eed more cleaning attention It is able to sense when larger amounts of dirt particles especially embedded dirt are removed To let you know that the Dirt FINDER fea ture is ready the red light will com...

Page 7: ...to top When using cleaning tools the agita tor will continue to rotate CAUTION To avoid personal injury or unnecessary wear to carpet and to prevent the cleaner from falling always place it at bottom...

Page 8: ...eaches the dotted line If more dirt than this accumulates your cleaner will not operate effectively Note All new carpet has loose fibers which can fill the bag quickly while vacuuming If you are using...

Page 9: ...placing tabs on bottom of door into opening C Press top of door to snap securely shut 9 3 5 3 2 A B C A C B Removing and installing filter bag Grasp filter bag collar A and pull collar from tube B Not...

Page 10: ...plate as shown in How to replace Replace belt if it is stretched cut or broken What to buy To assure effective operation use only genuine HOOVER belts with your clean er When purchasing a new belt as...

Page 11: ...place When agitator brushes are worn the agitator should be replaced To check condition of brushes discon nect cleaner from electrical outlet Move edge of a card across bottom plate while turning agit...

Page 12: ...amage Therefore do not add lubricant to motor bear ings The agitator is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoove...

Page 13: ...low Clearing blockages Disconnect cleaner from electrical outlet Low suction or pick up may be due to a blockage in the system Refer to the fol lowing steps to check for blockages continuing with eac...

Page 14: ...the appliance to one of the following authorized warranty service outlets Proof of purchase will be required before service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty S...