13
When finished cleaning, follow “After cleaning” instructions on
page 9 and “After using stair/upholstery nozzle” instructions on
page 13.
If additional cleaning is necessary, wait until the carpet is
completely dry before using the nozzle again.
NOTE: Check the recovery tank for fullness often.
Empty
tank if it appears full even if automatic shut-off (pg. 6) has not
engaged.
To avoid saturating carpet, do not use more than 4 wet
strokes over any one area. Always end with dry strokes.
Overlap strokes by one-half inch to help prevent streaking.
It is best to alternate wet and dry strokes as described above.
End with more dry strokes to aid in faster drying of carpet.
Release the trigger, lift nozzle, and position it against riser.
Pull nozzle
slowly
over carpet without pressing trigger (dry
stroke).
Position nozzle against the riser and slightly press nozzle into
carpet pile. Press the solution trigger and pull the nozzle
slowly
over the carpet (second wet stroke).
Cleaning carpeted stairs
Read “Before you begin cleaning” instructions on page 9.
Pre-spray the carpeted stair by holding the nozzle about one
inch above the carpet and push the wand forward while
pressing the solution trigger (equals one wet stroke).
Turn deep cleaner on.
Dry hands and plug deep cleaner into a
properly grounded
outlet.
Do not point stair/upholstery nozzle at people or pets.
To prevent machine from falling, use extra caution when
cleaning on stairs.
Do not place deep cleaner on stairs.
Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of
stairs to clean lower half.
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER Carpet/Upholstery Detergent.
Agitator brushes will not rotate while “solution tube” is
connected to deep cleaner.
Attach hose and solution tube as instructed on pages 11 and 12.
Drain solution tube by placing round end in sink, and raising
nozzle above your head. Press the trigger.
Disconnect hose and solution tube from deep cleaner.
Disconnect deep cleaner from electrical outlet.
Drain suction hose by turning deep cleaner on and holding
nozzle up for several minutes.
Do not press trigger.
After using stair/upholstery nozzle
Follow the instructions for “After cleaning” on page 9.
Stair/upholstery nozzle - Cleaning carpeted stairs
Replace recovery tank front panel.
Slide panel down until it
snaps firmly in place.
Snap clip back into positon making sure solution hose is not
pinched and moves freely.
CONVERTER
CONVERTER
CLIP
SOLUTION
HOSE
Occasionally, debris may become lodged inside of the hose at
the converter end.
To clean-out the hose, lift bottom of converter clip with a screw
driver and remove clip. Remove debris as shown.