Hoover SteamVac F5857955 Owner'S Manual Download Page 13

13

When finished cleaning, follow “After cleaning” instructions on
page 9 and “After using stair/upholstery nozzle” instructions on
page 13.

If additional cleaning is necessary, wait until the carpet is
completely dry before using the nozzle again.

NOTE:  Check the recovery tank for fullness often.

  

Empty

tank if it appears full even if automatic shut-off (pg. 6) has not
engaged.

To avoid saturating carpet, do not use more than 4 wet
strokes over any one area.   Always end with dry strokes.

Overlap strokes by one-half inch to help prevent streaking.

It is best to alternate wet and dry strokes as described above.
End with more dry strokes to aid in faster drying of carpet.

Release the trigger, lift nozzle, and position it against riser.
Pull nozzle 

slowly 

over carpet without pressing trigger (dry

stroke).

Position nozzle against the riser and slightly press nozzle into
carpet pile.  Press the solution trigger and pull the nozzle

slowly

 over the carpet (second wet stroke).

Cleaning carpeted stairs

Read “Before you begin cleaning” instructions on page 9.

Pre-spray the carpeted stair by holding the nozzle about one
inch above the carpet and push the wand forward while
pressing the solution trigger (equals one wet stroke).

Turn deep cleaner on.

Dry hands and plug deep cleaner into a 

properly grounded

outlet.

Do not point stair/upholstery nozzle at people or pets.

To prevent machine from falling, use extra caution when
cleaning on stairs. 

 

Do not place deep cleaner on stairs.

Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of
stairs to clean lower half.

Fill clean solution tank according to instructions on pages 7 and
8.  Use 5 ounces of HOOVER Carpet/Upholstery Detergent.

Agitator brushes will not rotate while “solution tube” is
connected to deep cleaner.

Attach hose and solution tube as instructed on pages 11 and 12.

Drain solution tube by placing round end in sink, and raising
nozzle above your head.  Press the trigger.

Disconnect hose and solution tube from deep cleaner.

Disconnect deep cleaner from electrical outlet.

Drain suction hose by turning deep cleaner on and holding
nozzle up for several minutes.  

Do not press trigger.

After using stair/upholstery nozzle

Follow the instructions for “After cleaning” on page 9.

Stair/upholstery nozzle - Cleaning carpeted stairs

Replace recovery tank front panel. 

 

Slide panel down until it

snaps firmly in place.

Snap clip back into positon making sure solution hose is not
pinched and moves freely.

CONVERTER

CONVERTER
CLIP

SOLUTION
HOSE

Occasionally, debris may become lodged inside of the hose at
the converter end.

To clean-out the hose, lift bottom of converter clip with a screw
driver and remove clip.  Remove debris as shown.

Summary of Contents for SteamVac F5857955

Page 1: ...tlet B that is properly installed and grounded in accordance with all local codes and ordinances Grounding Instructions Thank you for selecting a HOOVER product DO NOT RETURN THIS PRODUCT TO THE STORE Review this manual before oper ating deep cleaner Record and Retain This HOOVER deep cleaner is designed for deep cleaning of carpet and rugs It can also be used to clean carpeted stairs and upholste...

Page 2: ...certain the area is well ventilated when using detergents and other cleaners with this machine Keep detergents and other cleaners out of children s reach Do not use to pick up flammable or combustible liquids such as gaso line or use in areas where they may be present Do not pick up chlorine bleach drain cleaner gasoline or any other toxic material with this appliance Do not pick up anything that ...

Page 3: ...ing nozzle downward while pivoting it away from the handle at B 3 CORD HOOK Assembling deep cleaner The assembled cleaner will look like this drawing 4 Push bolts into holes on front of handle Fig 4 If bolts will not go through hole easily handle is not pushed completely down Place nuts in recessed areas on back of handle Hold each nut in place while tightening each bolt securely with a Phillips s...

Page 4: ... cord into cord clip on back of handle Pull cord tightn Fig 8 Attach lower hose holder Storing hose and nozzle on rack 13 Secure hose to rack at numbered locations as shown Fig 13 To store hose on rack begin by placing nozzle connector end of hose straight end into clip 1 on rack Fig 12 HANDLE CORD HOOK 12 CLIP 1 CLIP 1 14 1 2 4 3 2 2 Converter is stored in area as shown NOZZLE CONNECTOR HOLES HOS...

Page 5: ...ide selector to set brush speed on HI LO or OFF 16 Brush indicator spins when brushes are rotating 17 Nozzle 18 Upholstery and stair cleaning connection push door open to connect stair upholstery tool solution tube 19 Recovery tank latches one on each side of tank 20 ON OFF pedal 21 Handle release pedal step on pedal to lower handle to operating position The assembled deep cleaner will look like t...

Page 6: ...ry tank lid see illustration The deep cleaner will no longer pick up dirty solution and the motor sound will become noticeably higher in pitch When this happens turn deep cleaner off and empty recovery tank before continuing use Automatic shut off FLOAT DISK Check clean solution tank also it may need to be refilled NOTE Check the recovery tank often Empty tank when it appears full even if the auto...

Page 7: ...er back into position The tanks The clean solution tank holds the cleaning solution that is to be dispersed onto the surface to be cleaned How to fill Disconnect deep cleaner from electrical outlet TANK HANDLE Place deep cleaner handle in the upright locked position Carry tank to a sink Rotate tank cap counterclockwise and lift up to remove cap To remove tank press down on handle and pull forward ...

Page 8: ...et tank on furniture TANK HANDLE Turn deep cleaner off and disconnect from electrical outlet Step on handle release pedal and lower handle until it rests on the floor If cleaning stairs or upholstery remove hose as shown on pages 11 and 12 Rotate recovery tank latches outward one on each side of tank Lift tank off of deep cleaner and carry it to a sink or drain Unlatch back part of tank lid and re...

Page 9: ...arpets Stain removal varies with the type of spill time elapsed before removal carpet material and carpet type d Remove debris from recovery tank filter and rinse with clean water Available at additional cost if not included with your model g Toavoidwettingandpossibledamagetowoodfloors underneatharearugs carpet eithermovearearugs carpet to a non wood bare floor surface or place waterproof material...

Page 10: ... more dry strokes Continue using dry strokes until little water is visible passing through the recovery tank lid NOTE Check the recovery tank for fullness often Empty tank if it appears full even if automatic shut off pg 6 has not engaged When finished cleaning follow After cleaning instructions on page 9 Release trigger and slowly push deep cleaner forward over area just sprayed with solution dry...

Page 11: ...h arrow into groove opposite end of nozzle lip BARE FLOOR ATTACHMENT When finished cleaning follow After cleaning instructions on page 9 To pick up dirty solution release trigger and slowly move deep cleaner over area where solution has just been dis persed Use both forward and reverse strokes To release solution press trigger Slowly move deep cleaner forward and backward over area to be cleaned D...

Page 12: ...ected When the solution tube is connected to the deep cleaner the nozzle brushes will automatically be turned off and will not rotate when the deep cleaner is turned on even if the speed selector is in the HI or LO position TABS The tank lid is replaced in a hinge like manner Position front of lid under tabs on front of tank Rotate lid down onto tank Make sure lid is secure on all sides before cle...

Page 13: ...into a properly grounded outlet Do not point stair upholstery nozzle at people or pets To prevent machine from falling use extra caution when cleaning on stairs Do not place deep cleaner on stairs Hose length may require that machine be placed at the top of the stairs to clean upper half of stairway and at bottom of stairs to clean lower half Fill clean solution tank according to instructions on p...

Page 14: ...will not rotate while solution tube is connected to deep cleaner Attach hose and solution tube as instructed on pages 11 and 12 Be sure to check the cleaning code on your upholstery Use your HOOVER SteamVac deep cleaner only on upholstery marked W or W S Read Before you begin cleaning instructions on page 9 Cleaning upholstery and automobile interiors To clean in corners or creases lift the nozzle...

Page 15: ...ed securely fastened at connection of hood Solution tube on stair upholstery nozzle won t connect 1 Connector collar 1 Extend black tabs on pushed forward connector by pulling collar toward tube Brushes brush indicator won t rotate during floor cleaning 1 Indicator screen dirty 1 Remove clear cover over indicator and clean screen Replace cover see page 6 2 Speed selector on OFF 2 Move speed select...

Page 16: ...16 HOOVER and are registered trademarks THE HOOVER COMPANY NORTH CANTON OHIO 44720 R1 8 96 F5853 57 61 63 900 Litho USA 56518 086 ...

Reviews: