background image

Check bag indicator

(Available some models)

q

There are three conditions that will
cause the indicator to become
completely red:

 The bag is full; change bag.

2. Very fine materials (such as powder)
have been picked up, clogging the bag
pores; change bag, even if it is not full.

3. There is a blockage in the nozzle,
hose, tools or at the bag opening;
remove the blockage.

Suction regulator

q

The suction regulator (C) is located

 on the hand grip and may be used

to increase or decrease suction for

various cleaning tasks.

If power nozzle is difficult to push on

some carpet, open the suction regulator.

This will prevent damage to the belt.

Cleaning tools

A variety of useful cleaning tools is

included with your cleaner. If the clean-
er you have purchased does not include

the wall/floor brush, it is available at a

nominal cost from your Authorized
Hoover Dealer (Depot), a Hoover
Factory Service Center or by writing to

The Hoover Company, North Canton,

Ohio 44720.

Select the proper tool

q

1. Crevice tool 

may be used in

tight spaces, corners and along

edges in such places as dresser draw-
ers, upholstered furniture, stairs and
baseboards.

2. Furniture nozzle 

may be used for

upholstered furniture, draperies, tapes-

tries, mattresses, clothing, automobile

interiors and carpeted stairs.

3. Dusting brush 

may be used for

carved furniture, table tops, books,
lamps, lighting fixtures, Venetian blinds,
baseboards, shutters and registers.

4. Wall/Floor brush 

may be used for

walls and very irregular hard surface
floors such as brick and slate.
*Included with some models.

 

 

 For models with metal wands,

 Attach tools to hand  and 

attach tools to wand by pushing

 

 

 tic wands by rotating plastic latch

button projection on tool into spring

latch on wand. Depress center of latch

q

The cleaning tools are conveniently

 stored in the cleaner, as shown. To

ring until slots align; insert tool and

rotate ring to lock.

To remove tool, reverse above procedure.

t o   r e m o v e .

replace the wall/floor brush, be sure to
turn the nozzle connector toward the
cord hook or rewind pedal (B) before
pushing the brush in place.

Continued 

5

Summary of Contents for Futura S3559

Page 1: ...dy away from openings rotating agitator and other moving parts Do not operate cleaner in bare feet or when wearing open toe shoes or sandals l Do not pick up anything that is burning or smoking such a...

Page 2: ...ip snaps onto wands Suction regulator close for maxi mum suction open if power nozzle is difficult to push on some carpets or if lightweight rugs or draperies are being cleaned 10 Plastic latch ring l...

Page 3: ...atch A will automatically fasten To disconnect hose first remove hose cord plug from receptacle while pulling out on latch Then depress buttons shown in Fig 3 by arrows on hose con nector and pull up...

Page 4: ...o not change the plug in any way a After assembling cleaner plug cord into electrical outlet Turn cleaner on by depressing ON OFF pedal A To turn cleaner off depress pedal again qOn models without cor...

Page 5: ...ool q1 Crevice tool may be used in tight spaces corners and along edges in such places as dresser draw ers upholstered furniture stairs and baseboards 2 Furniture nozzle may be used for upholstered fu...

Page 6: ...clip E on bottom of I cleaner The nozzle must be nosi hUUl l LU wp q C lean stairs by placing cleaner on end as shown Clean stairs from c l tioned down as shown Lift up on wand to remove storage clip...

Page 7: ...r nozzle from wands and attach wands to hose Check for suction and remove any blockages q4 Before attaching power nozzle to wands check nozzle connector A While holding nozzle push nozzle con nector d...

Page 8: ...gitator To maintain cleaning effectiveness replace agitator if brushes do not touch edge of card How to replace The agitator may be replaced with either a single or double row of brushes Single row of...

Page 9: ...power cord not firmly plugged in l Plug firmly into receptacle on cleaner base l Broken or worn belt l Rep ace belt l Nozzle sealed to carpet l Open suction regulator Possible cause Possible solution...

Reviews: