background image

 
 

 

 

_________________________________________________________________________________________________ 

 

_________________________________________________________________________________________________ 

 

U279_LDX2_Bt_e_210630 

 

 

 1/3

 

 

 

 

Instruction Manual LDX2  

 

Apparatus 

 

 
 
The isolation/supply unit LDX2 is an auxiliary electrical appa-
ratus to which only approved intrinsically safe Höntzsch VA and 
FA sensors may be connected. The safety-related peak values of 
these sensors must comply with the technical data for the LDX2. 

 

 
 
 
 

 

 

 
1. Safety precautions   

 
Please read this Instruction Manual carefully before initial operation!  
Non-compliance can cause an explosion! 
 
Operation of the LDX2 is permissible outside the explosive atmosphere only and at an ambient tempera-
ture of max. +60 °C. The permissible supply voltage can be found on the type plate. 
 

 

2. Technical Data 

 
EC type examination certificate:

 IBExU 03 ATEX 1149

 

 
Marking  
 
 
 
 
 
Explosion protection:

 

[Ex ia] IIC/IIB

 

 
 

 

2.1 Electrical Data 

 
Nominal voltage:        

U

N

 = 24 VDC ±20 %

 

  

 
Rated voltage:     

 

U

m

 = 265 V 

 
Supply current circuit:   

U0

  

 

10.6 V, I0 

 

38 mA, P0

 

 

220 mW, R

i

 = 646 

Ω

  

 

 

 

 

trapezoid characteristic C

i

 = 0       L

i

 = 0 

 
Signal circuit:    

 

U0

  

 

10.6 V, I0 

 

1.2 mA, P0

 

 

3.2 mW, R

i

 = 9 k

Ω

  

 

 

 

 

linear characteristic C

i

 = 0       L

i

 = 0 

Reviews: