_________________________________________________________________________________________________
____________________________________________________________________________
2/3 U279_LDX2_Bt_e_210630
Maximum permissible values for the
external capacitance and inductance:
Category
ia
Gas group IIB IIC
Supply
current C
0
16.2 µF 2.32 µF
c
signal circuit L
0
0 mH 0 mH
Supply
current C
0
1.5 µF
c
signal circuit L
0
0.15 mH
Supply
current C
0
4 µF 0.5 µF
c
signal circuit L
0
1 mH 1 mH
3. Installation
The current European Specifications for Assembly, the recognised standards of good practice, User Infor-
mation FA/VA and this Instruction Manual apply.
Connect the designated terminals for PA/PE connection to the mains PA/PE!
4. Maintenance
Any maintenance or repair work to the equipment is to be carried out solely by Höntzsch GmbH & Co. KG.
Terminal connections:
PA/PE connection
PA
= 1
Power supply
0 V
= 2
24 V
= 3
Output 1
Optoc
= 5
Optocoupler -
= 6
Output 2
Optoc
= 7
Optocoupler -
= 8
Terminal connections:
sensor screen
S
= 11
sensor signal 2
F
= 13
sensor power supply
V+
= 14
reference potential
G
= 15
sensor signal 1
F
= 16
not assigned, free: 4, 9, 10, 12